Case: T12DV05573
Case Details
Entered Date:
07/02/2012
Applicant:
SHERWOOD GARDENS 200 LTD ATTN: DAN FELGER
Description:
SHERWOOD GARDEN APTS - CEILING FAN SPARKS WHEN TURNED ON. PIPES UNDER KITCHEN SINK LEAKING...SHOWER PIPES LEAKING, DRYWALL FALLING APART. CABINETS FALLING APART. TRASH/DEBRIS ALL OVER PROPERTY - LAUNDRY ROOM WIRING NOT UP TO CODE.
Case Violations
Case Number: T12DV05573
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
Violation Date | Code Statue |
---|---|
07/06/2012 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
07/06/2012 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
07/06/2012 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
07/06/2012 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
07/06/2012 | T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism. |
07/06/2012 | T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element. |
Outstanding Inspections
Case Number: T12DV05573
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/10/2012 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | RMENDOZA | Extension granted | |
10/10/2012 | NPO(PL)-PLUMBING SYSTEM & FX | RMENDOZA | Extension granted | |
10/10/2012 | NPO - EXT. BUILDING MAINTENANC | RMENDOZA | Extension granted | |
10/10/2012 | NPO - INT. BUILDING MAINTENANC | RMENDOZA | Extension granted |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV05573
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/05/2012 | INSP - INITIAL CODE ENFORCMENT | RMENDOZA | Approved | KITCHEN SINK IS LEAKING. SIGNS OF DETERIORATION UNDER THE SINK TO INCLUDE MOLD ALONG THE WALL AREA. THE CABINET BASE IS MISSING. WALL WAS WET AT THE TIME OF THE INSPECTION. KITCHEN FAN SHOW BURNT WIRES. BATHTUB IS NOT PROPERLY SEALED. AREA ABUTTS KITCHEN AREA AND MAY BE CONTRIBUTING TO THE WATER DAMAGE ALONG THE WALL. WALL BEHIND THE TOILET IS DETERIORATED AND SHOWS SIGNS OF COLLAPSE. MAIN BEDROOM CLOSET HAS AN ACCESS COVER TO THE BATHTUB THAT IS NOT SECURE. INSPECTION OF ACCESS OPENING SHOWS BATHTUB WATER LINE IS LEAKING. WALL IN THE LIVING ROOM NEAR THE CLOSET IS CRACKED. SOUTH BEDROOM WINDOW DOES NOT LOCK. EXTERIOR PORCH LIGHT IS INOPERABLE AND SHOWS BURNT WIRES. FACIA REPLACED AT THE REAR OF THE UNIT IS NOT PAINT PROTECTED. |
10/09/2012 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | Unit vacant. Repairs not started. Review in 90 days. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T12DV05573
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date | Name |
07/06/2012 | CONTACTED IN PERSON |
07/10/2012 | CONTACTED BY MAILING |
07/10/2012 | NOTICE OF VIOLATION ISSUED |
02/06/2013 | VIOLATION CLOSED |