Description:
LANDING IN BACKYARD REMOVED
Case Violations
Case Number: T12DV05490
Case Status: COMPLIAN
Case Description: RESIDENTIAL ZONING
Total Violations: 7
Violation Date | Code Statue |
---|---|
07/12/2012 | T.C. Ch. 6, IRC adopted. R311.3 LANDINGS AT EXTERIOR DOORS There shall be a landing or floor on each side of each exterior door. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches (914 mm) measured in the direction of travel. Exterior landings shall be permitted to have a slope not to exceed ΒΌ unit vertical in 12 units horizontal (2 percent). |
07/12/2012 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
07/12/2012 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
07/12/2012 | T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons. |
07/12/2012 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
07/12/2012 | T.C. Ch. 16, Sec. 16-12(e) ACCESSORY STRUCTURES. All accessory structures, including but not limited to detached garages, fences and walls, must be structurally sound and free of disrepair. Examples of disrepair include missing slats, posts or blocks, or damage, deterioration or rot. Fences and walls cannot be constructed or covered with materials not designed or commonly used for that purpose, such as pallets and tarps. Fences and walls must be properly anchored so as not to be in danger of failure or collapse. |
07/12/2012 | T.C. Ch. 16, Sec. 16-13(a) ACCUMULATION OF VEGETATION PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of the accumulation or untended growth of vegetation. The accumulation or untended growth of vegetation means the presence of plants on property that create a fire, safety or health hazard, or that attract vermin either on the property, on neighboring properties, or on both, and includes but is not limited to: (1) Any lawn grass that exceeds 6 inches in height; (2) All weeds that exceed 6 inches in height; (3) Dead trees and dead shrubs; (4) Dead palm fronds within ten feet of the ground, a structure, a fence or wall, or of any combustible other than the tree from which the fronds have grown; (5) Any tree, shrub, or other form of vegetation of any kind on the property or on the adjoining right-of-way, street, or alley that extends over or under the sidewalk space or roadway in a manner that may interfere with the reasonable use of the street, sidewalk, or alley for pedestrian or vehicular traffic of any kind or that may obstruct the view or light distribution of traffic-control devices or luminaries. Vegetation must be trimmed and maintained to provide an unobstructed pedestrian path a minimum 48 inches in width and 80 inches in height from grade. |
Outstanding Inspections
Case Number: T12DV05490
Case Status: COMPLIAN
Case Description: RESIDENTIAL ZONING
Total Outstanding Inspections - 5
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/31/2012 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | ESTEVENS | Item closed | |
10/31/2012 | NPO - INSECTS/PESTS | ESTEVENS | Item closed | |
10/31/2012 | NPO - VEGETATION NUISANCE | ESTEVENS | Item closed | |
10/31/2012 | NPO - INT. BUILDING MAINTENANC | ESTEVENS | Item closed | |
12/03/2012 | NPO - EXT. BUILDING MAINTENANC | ESTEVENS | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV05490
Case Description: RESIDENTIAL ZONING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/02/2012 | INSP - INITIAL CODE ENFORCMENT | ESTEVENS | Approved | At site, no access to home or trailer. Property fenced. Left notice in mailbox to call me for an appointment. F/U 2 days. |
12/03/2012 | INSP - FOLLOW UP CODE ENFORCE | ESTEVENS | Approved | At site, issues abated, close case. |
Completed Activity Special Conditions
Case Description - RESIDENTIAL ZONING
Case Number - T12DV05490
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date | Name |
10/26/2012 | CONTACTED BY PHONE |
07/12/2012 | CONTACTED BY MAILING |
10/09/2012 | CONTACTED BY EMAIL |
07/12/2012 | NOTICE OF VIOLATION ISSUED |
12/04/2012 | VIOLATION CLOSED |
08/22/2012 | REINSPECTION FEE - FIRST |