Case: T12DV05281
Case Details
Entered Date:
06/26/2012
Applicant:
DEMIRJIAN MARTIN
Description:
SWAMP COOLER NOT WORKING AT ALL - KIDS IN HOME ------ 100 DEGREES AT 1:00PM ON 06.25.12
Case Violations
Case Number: T12DV05281
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 8
| Violation Date | Code Statue |
|---|---|
| 07/06/2012 | T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools. |
| 07/06/2012 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 07/06/2012 | T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced. |
| 07/06/2012 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 07/06/2012 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 07/06/2012 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
| 07/06/2012 | T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons. |
| 07/06/2012 | T.C. Ch. 16, Sec. 16-11(f)(6) All repair work shall be done in a workman like manner. |
Outstanding Inspections
Case Number: T12DV05281
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/16/2012 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | RMENDOZA | Item closed | |
| 10/16/2012 | NPO(PL)-WATER HEATERS | RMENDOZA | Item closed | |
| 10/16/2012 | NPO(HC)-COOLING | RMENDOZA | Item closed | |
| 10/16/2012 | NPO - SMOKE ALARMS | RMENDOZA | Item closed | |
| 10/16/2012 | NPO - INT. BUILDING MAINTENANC | RMENDOZA | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV05281
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/28/2012 | INSP - INITIAL CODE ENFORCMENT | RMENDOZA | Approved | FRONT DOOR FRAME IS BROKEN. BACK SLIDING GLASS DOOR REPLACED AND THE BLOCK IS EXPOSED AND THE WORK IS UNFINISHED. REAR PORCH LIGHT IS INOPERABLE. APPEARS TO BE CONNECTED THROUGH THE WALL, POSSIBLY TO THE KITCHEN OUTLET. COOLER PADS AND THE WATER DISTRIBUTION AREA OF THE COOLER IS EXTREMELY DETERIORATED WITH A HIGH BUILD UP OF CALCIUM. WATER HEATER LACKS A PROPER TPRV PIPE. UNIT LACKS SMOKE DETECTORS. BATHROOM GFI IS INOPERABLE AND LACKS A COVER PLATE. OPEN GROUNDS THROUGHOUT THE UNIT. WEST WALL KITCHEN OUTLET IS INOPERABLE. BATHROOM WINDOW DOES NOT OPEN/SHUT PROPERLY. MISSING/BROKEN WINDOW CRANKS THROUGHOUT THE UNIT. MISSING SWITCH COVER PLATES THROUGOUT THE UNIT. |
| 10/16/2012 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | Unit vacant. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T12DV05281
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 06/27/2012 | CONTACTED BY PHONE |
| 07/10/2012 | CONTACTED BY MAILING |
| 07/10/2012 | NOTICE OF VIOLATION ISSUED |
| 10/19/2012 | VIOLATION CLOSED |