Case: T12DV04685
Case Details
Entered Date:
06/05/2012
Applicant:
HUMERTO FLORES
Description:
MOBILE HOME INSPECTION ON EXTERIOR ONLY
Case Violations
Case Number: T12DV04685
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 5
| Violation Date | Code Statue |
|---|---|
| 06/05/2012 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 06/05/2012 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
| 06/05/2012 | T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition. |
| 06/05/2012 | T.C. Ch. 6, IRC adopted. R311.3 LANDINGS AT EXTERIOR DOORS There shall be a landing or floor on each side of each exterior door. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches (914 mm) measured in the direction of travel. Exterior landings shall be permitted to have a slope not to exceed ΒΌ unit vertical in 12 units horizontal (2 percent). |
| 06/05/2012 | T.C. Ch. 6, IRC adopted. R311.7.8 HANDRAILS. Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. R311.7.8.1 - Height. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm). |
Outstanding Inspections
Case Number: T12DV04685
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/15/2012 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | RVIDAL | Item initialized | |
| 05/15/2012 | NPO - REFUSE/TRASH/DEBRIS | RVIDAL | Item initialized | |
| 05/15/2012 | NPO - EXT. BUILDING MAINTENANC | RVIDAL | Item initialized |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV04685
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/15/2012 | INSP - INITIAL CODE ENFORCMENT | CBIGMAN | Approved | NO CLEARANCE ON ELECTRICAL PEDESTAL, EXTERIOR LIGHT NO GLOBE, ADDED ELECTRICAL WOP, FRONT & BACK STEPS LACK RAILS, HASP ON FRONT DOOR (MGMT. REQUEST WE NOT ADDRESS THE HASP). BROKEN WINDOWS, REFUSE ON LOT. |
| 04/30/2013 | INSP - FOLLOW UP CODE ENFORCE | RVIDAL | Approved | All issues have been addressed with the meter being removed. The trailer is vacant and at this time will be listed as abanded. All utilities have been removed. Violation Abated, Close Case. RV. |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T12DV04685
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
| Date | Name |
| 05/01/2013 | VIOLATION CLOSED |