RMIN: Propane tanks stored outside that previously were connected to water heater. Interior kitchen cabinets falling apart due to water damage and mildew. Manager was informed of issues.

Case Violations

Case Number: T12DV03766
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 4
Violation Date Code Statue
05/29/2012 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
05/29/2012 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
05/29/2012 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
05/29/2012 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.

Outstanding Inspections

Case Number: T12DV03766
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
10/18/2012 NPO(EL)-WIRING/SWITCH/OUTLT/FX JHURD Item closed
10/18/2012 NPO(PL)-PLUMBING SYSTEM & FX JHURD Item closed
10/18/2012 NPO - EXT. BUILDING MAINTENANC JHURD Item closed
10/18/2012 NPO - WORK WITHOUT PERMIT JHURD Item closed
10/18/2012 NPO - INT. BUILDING MAINTENANC JHURD Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T12DV03766
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/17/2012 INSP - INITIAL CODE ENFORCMENT JHURD Approved VISITED SITE: MET WITH OCCUPANT, WENT OVER ISSUES. EXTERIOR SURFACE (STUCCO) FALLING OFF LEAVING HOLES, EXTERIOR WALL UNPROTECTED IN AREAS. ADDED ELECTRIC CIRCUITS, CONVENIENCE OUTLET FOR WASHING MACHINE, NOT WEATHER PROTECTED. ROMEX WIRING IN CONDUIT HAS NO BUSHING AT END OF ROMEX. BEDROOM CONVENIENCE OUTLET NOT SECURED TO WALL STICKING OUT FROM WALL. FRONT DOOR LACKS REQUIRED WEATHERSTRIPPING. NEW HOT WATER HEATER INSTALLED. (NO PERMIT ON RECORD). TUB/SHOWER AREA NO BATH DIVERTER FOR TUB. SHOWER WALL TILES CRACKED AND SEPERATING DOES NOT PROTECT WALL AS REQUIRED. KITCHEN SINK WASTE PIPES LEAK. N/O/V 30 DAYS.
10/18/2012 INSP - FOLLOW UP CODE ENFORCE JHURD Approved VISITED SITE: OWNER IS MILITARY BEEN OUT OF COUNTRY. GAVE EXTRA TIME. TALKED WITH OCCUPANT, YES OWNER HAS MADE REPAIRS. COMPLIANT @ THIS TIME CLOSE/CASE.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T12DV03766
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
09/14/2012 CONTACTED BY PHONE
06/05/2012 CONTACTED BY MAILING
06/05/2012 NOTICE OF VIOLATION ISSUED
10/25/2012 VIOLATION CLOSED

Documents

File Name Document Type  
NOV 5-30-12.PDF DOCUMENTS VIEW