Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T12DV00752
Case Details
Entered Date:
02/03/2012
Applicant:
MELVIN L & MARY JO COLYER JT/RS
Description:
Infested with termites in bedroom and bathroom area, which shows obvious signs of damage. Other Min. Housing issues. Informed Owner about a month and a half ago.
Case Violations
Case Number: T12DV00752
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
| Violation Date | Code Statue |
|---|---|
| 02/09/2012 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 02/09/2012 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 02/09/2012 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
| 02/09/2012 | T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism. |
| 02/09/2012 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
| 02/09/2012 | T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons. |
Outstanding Inspections
Case Number: T12DV00752
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/13/2012 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | RVIDAL | Item closed | |
| 04/13/2012 | NPO - INSECTS/PESTS | RVIDAL | Item closed | |
| 04/13/2012 | NPO - SMOKE ALARMS | RVIDAL | Item closed | |
| 04/13/2012 | NPO - EXT. BUILDING MAINTENANC | RVIDAL | Item closed | |
| 04/13/2012 | NPO - INT. BUILDING MAINTENANC | RVIDAL | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV00752
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/08/2012 | INSP - INITIAL CODE ENFORCMENT | RVIDAL | Approved | MET WITH THE TENANT AND LOOKED AT THE VIOLATION IN THE UNIT. FOUND WHERE THE WINDOWS IN THE LIVING ROOM AND KITCHEN ARE HARD TO OPEN AND CLOSE BY NOT SLIDING, ELECTRICAL LACKING A BLANK COVER OVER WHERE A BREAKER REMOVED AND NOT LABLELED COMPLETLY, FORCED AIR FURNACE HAS AN EXTENSION CORD FROM AN OUTLET IN THE LIVING ROOM GOING THROUGH A CLOSET INTO THE FURNACE ROOM, WOOD TRIM HAS BEEN REPLACED AND NOT SEALED FOR THE WEATHERIZATION DUE TO BEING ON THE EXTERIOR WALL, THE BEDROOMS HAVE TUNNELS OF TERMITS THROUGH-OUT THE CEILINGS AND ON THE DOOR JAMB, FRONT DOORS LACKING WEATHER-STRIPPING AND LACKING SMOKE DETECTORS. WILL DO N.O.V. RV. |
| 04/13/2012 | INSP - FOLLOW UP CODE ENFORCE | RVIDAL | Approved | ALL ISSUES HAVE BEEN ADDRESSED. VIOLATION ABATED, CLOSE CASE. RV. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T12DV00752
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 03/19/2012 | CONTACTED BY PHONE |
| 02/15/2012 | CONTACTED BY MAILING |
| 02/15/2012 | NOTICE OF VIOLATION ISSUED |
| 04/26/2012 | VIOLATION CLOSED |