Description:

No Heat and over Occupancy. Complanent stated that there is 6 people living in the house and DSD zoning states only 4 unrelated people can live in the house.

Case Violations

Case Number: T12DV00453
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 3
Violation Date Code Statue
02/03/2012 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
02/03/2012 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
02/03/2012 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.

Outstanding Inspections

Case Number: T12DV00453
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
03/08/2012 NPO(EL)-WIRING/SWITCH/OUTLT/FX RMENDOZA Item closed
03/08/2012 NPO(PL)-PLUMBING SYSTEM & FX RMENDOZA Item closed
03/08/2012 NPO(HC)-HEATING & VENTILATION RMENDOZA Item closed
03/08/2012 LUC - ZONING OTHER RMENDOZA Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T12DV00453
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/26/2012 INSP - INITIAL CODE ENFORCMENT RMENDOZA Approved WATER HEATER FLUE PIPE IS TAPED AT DOUBLE WALL DUE TO PIPE NOT FITTING CORRECTLY. SMOKE DETECTOR IS INOPERABLE. OPEN GROUND IN THE TENANTS BEDROOM. REVERSE NEUTRAL IN THE KITCHEN. HEATER IS IN OPERATION.
03/08/2012 INSP - FOLLOW UP CODE ENFORCE RMENDOZA Approved WATER HEATER VENT PIPER REPAIRED. SMOKE DETECTOR REPLACED. ELECTRICAL OUTLETS REPAIRED.

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T12DV00453
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
03/06/2012 CONTACTED BY PHONE
02/03/2012 CONTACTED IN PERSON
02/06/2012 CONTACTED BY MAILING
02/06/2012 NOTICE OF VIOLATION ISSUED
03/15/2012 VIOLATION CLOSED