Case: T12DV00340
Case Details
Entered Date:
01/18/2012
Applicant:
GUERRERO CLETO MENDOZA
Description:
Trailer has exposed wires and gas leak, windows broken, toilet not set on floor properly. Tenant is going into hospital for the next few days.
Case Violations
Case Number: T12DV00340
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 4
| Violation Date | Code Statue |
|---|---|
| 01/23/2012 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 01/23/2012 | T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced. |
| 01/23/2012 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 01/23/2012 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
Outstanding Inspections
Case Number: T12DV00340
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/23/2012 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | RDIAZ | Item closed | |
| 02/23/2012 | NPO(PL)-PLUMBING SYSTEM & FX | RDIAZ | Item closed | |
| 02/23/2012 | NPO - INT. BUILDING MAINTENANC | RDIAZ | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV00340
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/23/2012 | INSP - INITIAL CODE ENFORCMENT | RDIAZ | Approved | 1/19/12 9:14AM, SP K: OCCUPANT DAIEL BARTLETT, PH # 31-0043. INSPECTION OF TRAILIER, NO FACE PLATES ON OUTLETS LIVING ROOM (2). HEATER NOT WORKING DUE TO GAS LEAK, TENANT PROVIDED WITH ELECTRIC FAN HEATER. RUNNNING WATER. LOOSE TOILET BOWL IN BATHROOM. MET WITH PROPERTY OWNER: HE STATED THAT TENANT IS IN THE PROCESS OF BEING EVICTED FOR NON-PAYMENT OF RENT. EXPLAIN TO PROPERTY OWNER HE WAS STILL RESPONSIBLE FOR REPAIRS IN TRAILER UNTIL HE IS EVICTED. STATED THAT HE WILL START REPAIRS ON TRAILER. ADVISED HIM OF NOTICE OF VIOLATIONS WILL BE SENT TO HIS HOME ADDRESS FOR REPAIRS ON TRAILER SP K. |
| 02/23/2012 | INSP - FOLLOW UP CODE ENFORCE | RDIAZ | Approved | 2/22/12 10:25AM, MADE CONTACT WITH PERSON CLEANING THE TRAILER #K, OCCUPANT HAS BEEN EVICTED FOR NON PAYMENT OF RENT, ALL VIOLATIONS ON SITE HAVE BEEN CORRECTED VIOLATIONS ABATED CLOSE CASE. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T12DV00340
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 01/20/2012 | CONTACTED BY PHONE |
| 01/31/2012 | CONTACTED BY MAILING |
| 01/20/2012 | CONTACTED BY EMAIL |
| 04/26/2012 | VIOLATION CLOSED |