THOMAS A. & JANA H. TARTER JT/RS
Description:
Resident built block wall, water heater storage/attic space on roof, enclosed garage, and turned space into bedroom all without permits.
Case Violations
Case Number: T12DV00185
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Violations: 1
| Violation Date | Code Statue |
|---|---|
| 02/07/2012 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
Outstanding Inspections
Case Number: T12DV00185
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/29/2013 | NPO - WORK WITHOUT PERMIT | AVINDIOL | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV00185
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/13/2012 | INSP - INITIAL CODE ENFORCMENT | AVINDIOL | Approved | ON SITE HAD ALREADY ARRANGED A MEETING WITH OWNER OF PROPERTY // WALKED ME THRU PROPERY VERY ACCOMODATING// APPOX 2005 - 2 NEW PONY WALLS UNDER 4FT ADDED IN FRONT YARD ON BOTH EAST AND WEST SIDES NON ISSUE // WALL ALONG EASTSIDE OVER 6FT RUNS ALL THE WAY TO THE BACK - WILL NEED A PERMIT // STORAGE ROOM ADDED ON EASTSIDE OF HOME APPROX 6X8FT STUCCOED HAS A WATER HEATER INSIDE -BOTH WILL NEED A PERMIT // WEST SIDE OF HOME ANOTHER STORAGE/PORCH AREA ADDED FRAMING STAGE APPROX 6X18FT ANOTHER HOT WATER HEATER ADDED IN THERE - BOTH WILL NEED A PERMIT // PARAPET ROOF ADDED ON WESTSIDE OF HOME ADDED IN 2002 WILL ALSO NEED A PERMIT // NOV TO FOLLOW // AV |
| 03/29/2012 | INSP - FOLLOW UP CODE ENFORCE | AVINDIOL | Approved | 03/29/12 ON SITE FOR FOLLOW UP // REMOVE PARAPET FROM PROPERTY ON WEST SIDE OF HOME // REMOVED STORAGE SHED ALSO ON WEST SIDE OF HOME // PUT HOT WATER HEATER INTO A PRE FAB METAL HOTWATER CLOSET FROM HOME DEPOT WITH A DRIP PAN ON BOTTOM // ADDED CORSE OF BLOCK ON EASTSIDE WALL REMOVED NOW BACK TO ORIGINAL WALL UNDER 6FT // ADDED STORAGE ROOM ALONG EASTSIDE OF HOME REMOVED TO INCLUDE HOT WATER HEATER WAS ALSO REMOVED // WENT THRU DSD AND WAS TOLD WHAT TO DO TO REMOVE VIOLATIONS // WHICH HE DID WILL MOVE TO CLOSE OUT THIS CASE // AV |
Completed Activity Special Conditions
Case Description - WORK WITHOUT PERMITS-RESIDENTL
Case Number - T12DV00185
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 02/07/2012 | CONTACTED BY MAILING |
| 02/07/2012 | NOTICE OF VIOLATION ISSUED |
| 05/01/2012 | VIOLATION CLOSED |
| 02/07/2012 | RESEARCH |