Case: T12DV00057
Case Details
Entered Date:
01/05/2012
Applicant:
ULRICH ROGER L & ELLEN D JT/RS
Description:
LIVING CONDITIONS. TERMITES
Case Violations
Case Number: T12DV00057
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 9
Violation Date | Code Statue |
---|---|
01/05/2012 | T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced. |
01/05/2012 | T.C. Ch. 16, Sec. 16-14(c) BUILDINGS AND STRUCTURES CONSTITUTING A NUISANCE. All buildings and structures are to be maintained so as not to pose a threat to the health and safety of any person or persons. The condition of a building or structure that meets any or all of the following is a public nuisance, is a violation of this chapter, and subjects the building or structure to abatement as provided in Article VI of this chapter, including demolition as provided in section 16-65: (3) The building, structure or any portion thereof has been damaged by fire, earthquake, wind, flood or any other cause, to such an extent that the structural strength or stability thereof is materially less than it was before the damage and is less than the minimum requirements of the building code for new buildings of similar structure, purpose or location. |
01/05/2012 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
01/05/2012 | T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. |
01/05/2012 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
01/05/2012 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
01/05/2012 | T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition. |
01/05/2012 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
01/05/2012 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
Outstanding Inspections
Case Number: T12DV00057
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/29/2011 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | JHURD | Initial inspection | |
12/29/2011 | NPO(PL)-PLUMBING SYSTEM & FX | JHURD | Initial inspection | |
12/29/2011 | NPO - INSECTS/PESTS | JHURD | Initial inspection | |
12/29/2011 | NPO - EXT. BUILDING MAINTENANC | JHURD | Initial inspection | |
12/29/2011 | NPO - INT. BUILDING MAINTENANC | JHURD | Initial inspection |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV00057
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/29/2011 | INSP - INITIAL CODE ENFORCMENT | JHURD | Approved | VISITED SITE: WHILE ON SITE FOR NEIGHBOR, OCCUPANT STATED YOU SHOLD SEE MY PLACE. DONE INSP. SAFTY GLASS BY ENTRY DOOR BROKEN. DOOR & DOOR FRAME, WALL COMPERMISE BY TERMITES DESTRUCTION. ENTRY FOYER TILE, VYNIL BROKEN, CHIPPED, MISSING IN AREAS. LIVING ROOM CARPET FRAYED AT ENTRY, CARPET STRIP EXPOSED. CARPET BY SLIDING GLASS WINDOW MISSING. KITCHEN COOK STOVE EXHAUST FAN DOES NOT OPERATE. KITCHEN CABINETS MISSING DRAWER FACINGS. CEILING SHOWS EVIDENCE OF LEAK. HOLE IN DOOR. MECHANICAL EMERGRNCY DISCONNECT IN HEATER ROOM NOT PROPERLY SECURED TO WALL. DWELLING LACKS REQUIRED SMOKE DETECTORS. HALL LIGHT MISSING. BATHROOM WALL DETERIORATED FROM WATER LEAKS. INTERIOR EXTERIOR. BATHROOM FLOOR LACKS REQUIRED FLOOR PROTECTION. TILES/VYNIL. HOLES IN WALL. BATH VANITY TOP NOT PROPERLY SEALED. LIGHT FIXTURE LACKS REQUIRED PROTECTIVE COVER. BATH CABINETS & DRAWERS LACKS FACING. BEDROOM DOOR FRAME BROKEN. STRUCTURE WOOD SIDING AND FACIA LACKS REQUIRED PROTECTION, SEALENT. CARPORT HAS TERMITES, BROKEN 2X6 RAFTERS & FACIA RAW WOOD. N/O/V 30 DAYS. |
03/27/2012 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Approved | VISITED SITE: WALKED UNIT, TALKED WITH OCCUPANTS, ALL REPAIRS MADE, PERMIT # T12CM00663 FINALED. COMPLIANT. CLOSE/CASE. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T12DV00057
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date | Name |
01/19/2012 | CONTACTED BY MAILING |
02/17/2012 | CONTACTED BY EMAIL |
01/19/2012 | NOTICE OF VIOLATION ISSUED |
04/10/2012 | VIOLATION CLOSED |