Case: T12DV00016
Case Details
Entered Date:
01/03/2012
Applicant:
CARMEN J. GASTELO
Description:
TPD call. Location is the rear of property. Adobe structure material on east wall is falling apart. No water to residence. People living on site. Holes on the side of the house.
Case Violations
Case Number: T12DV00016
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 1
| Violation Date | Code Statue |
|---|---|
| 01/30/2012 | T.C. Ch. 16, Sec. 16-14(b)(3) ABATEMENT OF VACANT AND UNSECURED BUILDINGS. When ordered abated, a vacant and unsecured building shall be cleaned and secured as follows: a. All accumulated refuse that poses a fire or health hazard within or upon the property or premises shall be removed; and b. All unsecured doorway, windows, or exterior openings shall be barricaded in accordance with standards established by the code official, which shall be kept on file with the city clerk, and in accordance with section 16-12(a)(3) of this chapter; and c. Both the structure and the exterior premises shall be posted with signs that provide reasonable notice prohibiting entry (i.e., "No Trespassing" signs). |
Outstanding Inspections
Case Number: T12DV00016
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/10/2012 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | LPUMPHRE | Item closed | |
| 01/10/2012 | NPO - REFUSE/TRASH/DEBRIS | LPUMPHRE | Item closed | |
| 01/10/2012 | NPO - INT. BUILDING MAINTENANC | LPUMPHRE | Item closed | |
| 03/14/2012 | NPO(PL)-PLUMBING SYSTEM & FX | LPUMPHRE | Item closed | |
| 03/14/2012 | NPO - EXT. BUILDING MAINTENANC | LPUMPHRE | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV00016
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/13/2012 | INSP - INITIAL CODE ENFORCMENT | LPUMPHRE | Approved | No active water to unit B in rear. No one home at time of inspection. Spoke to property owner at main unit and advised of need to obtain active water service. Small accumulation of debris; rear unit has some dilapidation to exterior adobe towards front facing alley and NE section, but it is not extensive. Unable to access interior. Several cats in area. Roof appears in good condition. |
| 03/13/2012 | INSP - FOLLOW UP CODE ENFORCE | LPUMPHRE | Approved | Compliant; property remains vacant and is secure. |
Outstanding Case Activity Conditions
| Date | Name | Approved |
| 01/30/2012 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (4) All plumbing fixtures shall be connected to a public sewer system or to an approved private sewage disposal system, with the connections free from leaks, blockages, or other defects. All plumbing fixtures shall be connected to an approved system of water supply and provided with hot and cold running water necessary for its normal operation. T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. | Not Approved |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T12DV00016
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 01/24/2012 | CONTACTED BY PHONE |
| 01/24/2012 | CONTACTED IN PERSON |
| 01/30/2012 | NOTICE AND ORDER ISSUED |
| 01/30/2012 | NOTICE OF VIOLATION ISSUED |
| 03/14/2012 | VIOLATION CLOSED |