Case Details

Status:

COMPLETE

Type:

INSPECTION
Address:

Entered Date:

04/15/2011

Applicant:

WILLIAMS MICHAEL M & LAUER-WILLIAMS JEANNE TR

Description:

La Primavera landscaping 4/13/11

Outstanding Inspections

Case Number: T11FR00841
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
04/15/2011 VIOL - ADMINISTRATION MPursley Correction Required 102.4 Application of building code. The design and construction of new structures shall comply with the International Building Code, and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code, shall be made in accordance therewith. A Certificate of Occupancy shall be provided To obtain a Certificate of Occupancy or a replacement copy, contact the city of Tucson Development services Department (DSD) located at 201 N. Stone, (520) 791-5550.
04/15/2011 VIOL - BUILDING SVCS & SYSTEMS MPursley Correction Required 605.1 Abatement of electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the code official responsible for enforcement of the ICC Electrical Code. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used… Electrical blanks shall be placed in all open spaces within any electrical panel or box. _____ Place electrical blanks in any open void spaces in your electrical panel _____Replace non-approved wiring 605.5 Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring. Cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. _____ All extension cords shall be removed and/or replace with approved fused power strips.
04/15/2011 VIOL - HAZARDOUS MATERIALS,GEN MPursley Correction Required 2703.1 Maximum Allowable Quantities: Class IA Flammable liquids: 30gal. can be doubled with proper cabinet and doubled again if sprinklered.

Completed Inspections

Case Status: COMPLETE
Case Number: T11FR00841
Case Description: INSPECTION
Total Completed Inspections - 1
End Date Description Inspector Results Comments
06/02/2011 INSP - REINSPECTION MPursley Approved All corrections made 6/1/11