Case Details

Status:

COMPLETE

Type:

INSPECTION
Address:

Entered Date:

02/18/2011

Applicant:

CASH NET PROPERTIES LLC

Description:

Los Bateos fire inspection.

Outstanding Inspections

Case Number: T11FR00466
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
02/18/2011 VIOL - FIRE SERVICE FEATURES JLOYA Violation 505.1 Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. Address numbers shall be in accordance with Pima County address display requirements. Building < 50 feet from the curb require 12" numbers displayed on the building. Buildings > 50 feet from the curb require 15" numbers displayed on the building. Tenant space numbers shall be 3" Address range may be displayed in 12" numbers on the building. ___ Paint existing number's to contrast with building.
02/18/2011 VIOL - MEANS OF EGRESS JLOYA Violation 1011.2 - Illumination. Exit signs shall be internally or externally illuminated. _____ Repair/replace exit signs
02/18/2011 VIOL - COMPRESSED GASES JLOYA Violation 3003.3 Security. Compressed gas containers, cylinders, tanks and systems shall be secured against accidental dislodgment and against access by unauthorized personnel. *** Secure gas cylinder in an approved manner to avoid accidental dislodgment.

Completed Inspections

Case Status: COMPLETE
Case Number: T11FR00466
Case Description: INSPECTION
Total Completed Inspections - 2
End Date Description Inspector Results Comments
02/18/2011 INSP - FULL JLOYA Approved Correct the following fire code violations found during life/safety fire inspection. Thank you for your cooperation, for any questions please contact inspector Jorge Loya @ 837-7118, Fax 791-5346. Received by_________________ Date__________
03/10/2011 INSP - REINSPECTION JLOYA Approved Violations abated.