Case Details

Status:

COMPLETE

Type:

INSPECTION
Address:

Entered Date:

02/07/2011

Applicant:

DIB GROUP INVESTMENTS LLC & BCB GROUP

Description:

FULL INSPECTION

Outstanding Inspections

Case Number: T11FR00354
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
02/07/2011 INSP - FULL JDAVIS Correction Required 1. _____ 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exits: " Places of detention or restraint. " In buildings in occupancy Group A having an occupant load of 300 or less, Groups B, F, M and S, and in churches, the main exterior door or doors are permitted to be equipped with key-operated locking devices from the egress side provided: 2.1. The locking device is readily distinguishable as locked, 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25mm)high on a contrasting background, 2.3. The use of the key-operated locking device is revokable by the fire code official for due cause. 2. _____ 605.5 Extension Cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. - UNDER MAIN DESK - GOING TO ILLEGAL OUTLET GOING THROUGH THE WALL - ATTACHED T OSTRUCTURE NEAR "AUTOGAURD" - UPSTAIR TO T.V./SECURITY - TINT AREA - ATTACHED TO CORD GONIG THROUGH WALL TO THE PARTS CLEANER 3. _____ 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. -REPLACE THE MISSING COVER ON THE J-BOX NEAR THE MICROWAVE 4. _____ 407.2 Material Safety Data Sheets. Material Safety Data Sheets (MSDS) for all hazardous materials shall be readily available on the premises. -PROVIDE MSDS FOR AL LCHEMICALS 5. _____ 407.4 Training. Persons responsible for the operation of areas in which hazardous materials are stored, dispensed, handled or used shall be familiar with the chemical nature of the materials and the appropriate mitigating actions necessary in the event of a fire, leak or spill… - Train employees on the location of the MSDS/ Hazardous Communication Program 6. _____ 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. - DUE JANUARY 7. _____ 2703.5.1 Markings. Individual containers, cartons or packages shall be conspicuously marked or labeled in an approved manner. Rooms or cabinets containing compressed gases shall be conspicuously labeled: -OUTSDE REAR -REPLACE MISSING BUNGS 8. _____ 1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted. - MIDDLE REAR EXIT 9. _____ 315.2 Storage in buildings. Storage of combustible materials in buildings shall be orderly. Storage shall be separated from heaters or heating devices by distance or Shielding so that ignition cannot occur -MAINTAIN GOOD HOUSEKEEPING IN THE DETAIL SHOP 10. _____ 1028.2 Reliability. Required exit accesses, exits or exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency when the areas served by such exits are occupied. Security devices affecting means of egress shall be subject to approval of the fire code official. - CURRENTLY THE EXIT NI TEH DETAIN SHOP IS INADEQUATE. AN AWNNIG HAVE BEEN ERECTED THAT REDUCES BOTH THE HEIGHT AND WIDTH FO THE EGRESS DOOR.