Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

11/29/2011

Applicant:

ULRICH ROGER L & ELLEN D JT/RS

Description:

TERMITE INFESTATION, HOLES IN WALLS, WIRES HANGING OUT OF WALLS, HEATING INOP

Case Violations

Case Number: T11DV09612
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 7
Violation Date Code Statue
01/04/2012 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
01/04/2012 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
01/04/2012 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
01/04/2012 T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability.
01/04/2012 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
01/04/2012 T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced.
01/04/2012 T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition.

Outstanding Inspections

Case Number: T11DV09612
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
12/29/2011 NPO(EL)-WIRING/SWITCH/OUTLT/FX JHURD Initial inspection
12/29/2011 NPO(PL)-PLUMBING SYSTEM & FX JHURD Initial inspection
12/29/2011 NPO - INSECTS/PESTS JHURD Initial inspection
12/29/2011 NPO - SMOKE ALARMS JHURD Initial inspection
12/29/2011 NPO - INT. BUILDING MAINTENANC JHURD Initial inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T11DV09612
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/29/2011 INSP - INITIAL CODE ENFORCMENT JHURD Approved VISITED SITE: MET WITH OCCUPANT, ALLOWED INSP. HALL BEDROOM OUTLET BROKEN BATHROOM TUB/SHOWER DIVERTER DOES NOT OPERATE PROPERLY. SKY LIGHT SHOW WHERE LEAKS. TOILET NOT INSTALLED PROPERLY. DWELLING LACKS REQUIRED SMOKE ALARMS. KITCHEN STOVE EXHAUST FAN DOES NOT OPERATE. KITCHEN DRAWERS, FACE AND TRACKS FALLING OFF AND OR MISSING. EXTERIOR DOOR WOOD FRAME DAMAGED, HOLES. TRASH/DEBRIS BEHIND SHED. RAW WOOD ON SHED. 2X6 RAFTERS BROKEN. MAIN DWELLING FACIA BROKEN, SPLIT. MAIN DWELLING EXTERIOR SIDING SHOWS RAW WOOD, SEALENT MISSING. N/O/V TO BE ISSUED. 30 DAYS.
03/27/2012 INSP - FOLLOW UP CODE ENFORCE JHURD Approved VISITED SITE: NEW OCCUPANT. TALKED WITH NEW OCCUPANT. WENT OVER ISSUES ON N/O/V. CONFIRMED THAT THEY MUST HAVE TAKEN CARE OF ISSUES DUE TO ISSUES ON N/O/V NO LONGER EXSIST. NO PROBLEMS IN HOUSE. COMPLIANT. CLOSE/CASE.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T11DV09612
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
01/19/2012 CONTACTED BY MAILING
02/17/2012 CONTACTED BY EMAIL
01/19/2012 NOTICE OF VIOLATION ISSUED
04/06/2012 VIOLATION CLOSED