Case: T11DV09584
Case Details
Entered Date:
11/28/2011
Applicant:
DOUG SIEPKER
Description:
SPACE # 122 TOILET INOPERABLE BECAUSE OWNER UNABLE TO REPAIR HEATER NOT BLOWING TO ALL VENTS. ONLY ONE DOOR OPERABLE FOR EGRESS - REAR DOOR BOLTED SHUT
Case Violations
Case Number: T11DV09584
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 9
| Violation Date | Code Statue |
|---|---|
| 12/06/2011 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 12/06/2011 | T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced. |
| 12/06/2011 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 12/06/2011 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 12/06/2011 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
| 12/06/2011 | T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element. |
| 12/06/2011 | T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition. |
| 12/06/2011 | T.C. Ch. 16, Sec. 16-11(f)(2) Every ceiling, roof, and ceiling and roof support must be sufficient to carry imposed loads safely, and must not buckle, sag or split due to defective material or deterioration. |
| 12/06/2011 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
Outstanding Inspections
Case Number: T11DV09584
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 7
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/05/2011 | NPO - EGRESS | ESTEVENS | Item closed | |
| 12/30/2011 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | ESTEVENS | Follow-up inspection | |
| 12/30/2011 | NPO(PL)-PLUMBING SYSTEM & FX | ESTEVENS | Follow-up inspection | |
| 12/30/2011 | NPO(HC)-HEATING & VENTILATION | ESTEVENS | Follow-up inspection | |
| 12/30/2011 | NPO - SMOKE ALARMS | ESTEVENS | Follow-up inspection | |
| 12/30/2011 | NPO - EXT. BUILDING MAINTENANC | ESTEVENS | Follow-up inspection | |
| 12/30/2011 | NPO - INT. BUILDING MAINTENANC | ESTEVENS | Follow-up inspection |
Completed Inspections
Case Status: COMPLIAN
Case Number: T11DV09584
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/05/2011 | INSP - INITIAL CODE ENFORCMENT | ESTEVENS | Approved | At site, weather stripping around front door coming off. Light coming in around top and bottom of door. Back door not properly installed, light coming through around door. No door knob, improper locks on door. Bathroom toilet leaks water at supply hose. Bathroom ceiling at tub/shower area has a hole. Heater vent in Master Bedroom is covered. Smoke detectors missing in bedrooms. Kitchen and laundry cabinet, some doors are glued shut. Living room floor near rear window has a soft spot. Storage shed door is broken, corner trim is rotted out. Water leaks at supply hose near meter. Electrical dryer outlet not attached to wall. Oven door broken pass the stops. |
| 12/30/2011 | INSP - FOLLOW UP CODE ENFORCE | ESTEVENS | Approved | Contatced by owner to inspect trailer before 30 days period. At site, meet with owner. Over 50% of issues corrected. F/U 30 days. |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T11DV09584
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 12/06/2011 | CONTACTED BY MAILING |
| 12/06/2011 | NOTICE OF VIOLATION ISSUED |
| 03/02/2012 | VIOLATION CLOSED |