Case Details

Status:

COMPLIAN

Type:

WORK WITHOUT PERMITS-RESIDENTL
Address:

Entered Date:

11/21/2011

Applicant:

FEDERAL NATIONAL MORTGAGE ASSN

Description:

W/O/P, REPLACE GAS & WATER LINES, NEW HEATING APPLIANCE, HAZARDOUS ELECTRICAL

Case Violations

Case Number: T11DV09424
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Violations: 3
Violation Date Code Statue
11/21/2011 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
11/21/2011 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
11/21/2011 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.

Outstanding Inspections

Case Number: T11DV09424
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
11/21/2011 NPO(EL)-MAIN/PANEL/SUB/DISCONT HLOPEZ Item initialized
11/21/2011 NPO(EL)-WIRING/SWITCH/OUTLT/FX HLOPEZ Item initialized
11/21/2011 NPO - WORK WITHOUT PERMIT HLOPEZ Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T11DV09424
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Completed Inspections - 2
End Date Description Inspector Results Comments
11/17/2011 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VIOLATIONS PRESENT Visited site, made contact w/onsite contractor & crew, crew in process of remodeling, T11PL01862 for replace gas line issued but does not cover no going work such as Hot water heater has been replace, lacks T.R.P. drain valve, gas heating appliance being replaced, new exterior copper water lines installed, along w/3 prong receptacles lacking ground. Kitchen 3 prong receptacle have no G.F.I.C. protection, Main disconnect lacking several breaker blank covers, lacking directory at sub-panel. Due to work being done & no permit to cover issues stop work order posted. NOV to follow
05/15/2012 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved Research done prior to site inspection, T11PL01160 still current, expires 7/21/12, no activity since 1/23/12, T11EL03327 final 1/10/12, T12CM00234 in issued status, no inspections as of yet, expires 7/30/12. Site inspection found structure occupied. Contact made w/new owner on site. Stated recently purchased property, informed him of issues regarding furnace, stated no furnace has been installed & realtor sold property as is. Owner unaware of pending violations. Inspector to contact w/Rathman realty regarding unabated violation. Case to be reassigned due to inspector leaving department. Possibly move to citation process for unabated issues. Review w/supervisor. Schedule 30 day fw/up. Apply 1st fee

Completed Activity Special Conditions

Case Description - WORK WITHOUT PERMITS-RESIDENTL
Case Number - T11DV09424
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
11/23/2011 CONTACTED BY PHONE
11/23/2011 CONTACTED BY MAILING
11/23/2011 CONTACTED BY EMAIL
09/24/2013 VIOLATION CLOSED
01/10/2012 RESEARCH
11/21/2011 NOTICE OF VIOLATION ISSUED