Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING
Address:

Entered Date:

10/18/2011

Applicant:

CASA BONITA I & II LP

Description:

TFD REQUEST FOR INPSECTOR/ COMMERCIAL APT FIRE

Outstanding Inspections

Case Number: T11DV08489
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
11/21/2011 NPO(EL)-WIRING/SWITCH/OUTLT/FX JHURD Follow-up inspection RESEARCH
11/21/2011 NPO(PL)-PLUMBING SYSTEM & FX JHURD Follow-up inspection RESEARCH
11/21/2011 NPO - INT. BUILDING MAINTENANC JHURD Follow-up inspection RESEARCH

Completed Inspections

Case Status: COMPLIAN
Case Number: T11DV08489
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/17/2011 INSP - INITIAL CODE ENFORCMENT GGOODMAN Approved VISITED SITE, MET WITH MANAGER SONYA VALENZUELA AND TFD INSPECTOR WAYNE CUMMINGS. TFD WAS NOT YET ABLE TO GET INTO THE STRUCTURE. ALL POWER TO THE STRUCTURE HAD BEEN TURNED OFF. THIS STRUCTURE CONSISTED OF 3 PODS/ 4 ROOMS EACH POD. EACH ROOM WAS ACTUALLY A EFFICIENCY WITH SMALL KITCHEN /DINING AND A BATHROOM. EACH ROOM HAD IT'S OWN LOCKING DOOR. WHILE WAITING I WALKED THE PREMISES WITH S/W GAS FOUND THERE WAS NO GAS TO THE PROPERTY. MET WITH TEP TO DETERMINE IF POWER COULD BE RESTORED TO THE MIDDLE AND EAST POD. MAIN SERVICE PANEL WAS CONNECTED TO A GUTTER BOX SERVING 3 MAIN DISCONNECTS, ONE FOR EACH POD. SINCE THERE WAS NO FIRE DAMAGE AND LITTLE SMOKE DAMAGE WE RESTORED POWER TO POD #3 AND TENANTS WERE ALLOWED TO STAY. WALKED CENTER POD WITH TFD FOUND ONLY (3) 2' X 2' HOLES IN THE DRYWALL CEILINGS TO ALLOW SMOKE TO ESCAPE, AND POD HAD MINOR SMOKE DAMAGED. SPOKE WITH MANAGER ASKED THAT TENANTS NOT BE ALLOWED TO RETURN TO UNIT UNTIL TOMORROW 10/18. WINDOWS WERE OPENED AND FANS PLACED IN UNIT. TENANTS WERE PLACED IN OTHER COPE FACILITIES FOR THE EVENING. DUE TO ONLY MINOR SMOKE DAMAGE, POWER WAS RESTORED TO CENTER POD #2 TO ALLOW FANS TO RUN. TENANTS WILL RETURN. MANAGEMENT AND OWNER SCOTT DAVEY WILL RE ASSESS TO DETERMINE IF COPE WANTS TENANTS IN THE UNITS, ESPECIALLY DURING CONSTRUCTION. POWER REMAINS OFF TO POD #3 WHERE FIRE ORIGINATED. ROOM 2109 WAS COMPLETELY FIRE DAMAGED ALTHOUGH NO STRUCTURAL DAMAGE TO RAFTERS & ROOF SHEATHING OR WALL STUDS. ALL DRYWALL WAS DAMAGED, PLUMBING FIXTURES AND SHOWER FIRE DAMAGED, DUCT WORK SMOKE DAMAGED, ELECTRICAL OUTLETS,SWITCHES, WIRING AND FIXTURES ALL FIRE DAMAGED. REMAINING UNITS 2110, 2111, AND 2112 AND LIVINGROOM AREA RECEIVED HEAVY SMOKE AND WATER DAMAGE. TENANTS IN POD #3 WERE PLACED BY RED CROSS UNDER TFD. REPRESENTATIVE FOR GENERAL PARNERSHIP SCOTT DAVEY ARRIVED ON SITE WITH PROPERTY MANAGER KIM FITCH. NOV FOR EMERGENCY ABATEMENT WAS ISSUED TO MR DAVEY. POD #3 WAS POSTED. COPE MAINTANENCE PERSONAL TOOK RESPONSIBILITY FOR SECURING THE UNIT. WAITED UNTIL MAINTANENCE SHOWED WITH MATERIALS TO BOARD THE WINDOW OPENINGS. LOCKS ON FRONT DOOR WERE CHANGED AND TENANT INFORMED TO MAKE ARRAINGEMENTS WITH MANAGER SONYA VALENZUELA TO REMOVE BELONGINGS. *** SEE ADDITIONAL NOTES IN CASE PACKET OR SIRE..
11/21/2011 INSP - FOLLOW UP CODE ENFORCE JHURD Approved Research

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T11DV08489
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
10/21/2011 NOTICE AND ORDER ISSUED
10/21/2011 NOTICE OF VIOLATION ISSUED
02/28/2012 VIOLATION CLOSED
11/21/2011 RESEARCH
10/21/2011 CALLBACK

Documents

File Name Document Type  
EMERGENCY CALL-OUT DOCS.PDF DOCUMENTS VIEW