RES: MINIMUM HOUSING
Address:

Entered Date:

09/22/2011

Applicant:

SUSAN ASHLEY

Description:

Cooler hardly works, leaks water, ceiling sagging.

Case Violations

Case Number: T11DV07549
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
Violation Date Code Statue
09/26/2011 T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools.
09/26/2011 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
09/26/2011 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
09/26/2011 T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition.
09/26/2011 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
09/27/2011 T.C. Ch. 16, Sec. 16-11(f)(6) All repair work shall be done in a workman like manner.

Outstanding Inspections

Case Number: T11DV07549
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
09/29/2011 NPO(EL)-MAIN/PANEL/SUB/DISCONT RMENDOZA Notice of violation
09/29/2011 NPO(PL)-WATER HEATERS RMENDOZA Notice of violation
09/29/2011 NPO - SMOKE ALARMS RMENDOZA Notice of violation
10/19/2012 NPO(EL)-WIRING/SWITCH/OUTLT/FX RMENDOZA Item closed
10/19/2012 NPO - INT. BUILDING MAINTENANC RMENDOZA Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T11DV07549
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
09/23/2011 INSP - INITIAL CODE ENFORCMENT RMENDOZA Approved ALL DOORS TO EXTERIOR OF STRUCTURE LACK PROPER WEATHER PROTECTION. LIVING ROOM CANISTER LIGHT IS NOT SECURED. KITCHEN CEILING SHOW SIGNS OF LEAKS. KITCHEN WALL NEAR THE SINK IS NOT PROPERLY REPAIRED. GFI IN THE KITCHEN IS INOP. REAR ADDITION CEILING IS DETERIORATED. EXPOSED ELECTRICAL AT THE WASHER/DRYER AREA. CENTER BEDROOM WINDOW DOES NOT OPEN. SOUTHEAST BEDROOM WINDOW CRANKS ARE INOP. CEILING SHOWS SIGN OF LEAKS. NORTHEAST BEDROOM DOOR IS BROKEN. LACKS VENT REGISTER. BATHROOM OUTLET IS INOP. WATER HEATER LACKS PROPER DRAIN PIPE. DOOR IS BROKEN. ELECTRICAL PANEL LACK A DEAD FRONT. UNIT LACKS SMOKE DETECTORS. LIGHT SWITCH COVER PLATES ARE MISSING THROUGHOUT THE UNIT.
10/19/2012 INSP - FOLLOW UP CODE ENFORCE RMENDOZA Approved GFI repaired. Seals on door repaired. Vent register installed. Close case.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T11DV07549
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 11
Date Name
09/27/2011 CONTACTED BY PHONE
04/10/2012 CONTACTED IN PERSON
09/29/2011 CONTACTED BY MAILING
03/26/2012 CONTACTED BY EMAIL
09/29/2011 NOTICE OF VIOLATION ISSUED
10/19/2012 VIOLATION CLOSED
04/12/2012 REINSPECTION FEE - FIRST
09/26/2011 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
09/26/2011 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.
09/27/2011 T.C. Ch. 16, Sec. 16-13(a) ACCUMULATION OF VEGETATION PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of the accumulation or untended growth of vegetation. The accumulation or untended growth of vegetation means the presence of plants on property that create a fire, safety or health hazard, or that attract vermin either on the property, on neighboring properties, or on both, and includes but is not limited to: (1) Any lawn grass that exceeds 6 inches in height; (2) All weeds that exceed 6 inches in height; (3) Dead trees and dead shrubs; (4) Dead palm fronds within ten feet of the ground, a structure, a fence or wall, or of any combustible other than the tree from which the fronds have grown; (5) Any tree, shrub, or other form of vegetation of any kind on the property or on the adjoining right-of-way, street, or alley that extends over or under the sidewalk space or roadway in a manner that may interfere with the reasonable use of the street, sidewalk, or alley for pedestrian or vehicular traffic of any kind or that may obstruct the view or light distribution of traffic-control devices or luminaries. Vegetation must be trimmed and maintained to provide an unobstructed pedestrian path a minimum 48 inches in width and 80 inches in height from grade.
09/27/2011 T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition.