Case: T11DV06930
Case Details
Entered Date:
08/30/2011
Applicant:
JOE Y & LORI J LILLEY
Description:
ELECTRICAL ISSUES, PLUMBING ISSUES. W.O.P.
Case Violations
Case Number: T11DV06930
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 4
| Violation Date | Code Statue |
|---|---|
| 08/30/2011 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 08/30/2011 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 08/30/2011 | T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition. |
| 08/30/2011 | T.C. Ch. 16, Sec. 16-12(e) ACCESSORY STRUCTURES. All accessory structures, including but not limited to detached garages, fences and walls, must be structurally sound and free of disrepair. Examples of disrepair include missing slats, posts or blocks, or damage, deterioration or rot. Fences and walls cannot be constructed or covered with materials not designed or commonly used for that purpose, such as pallets and tarps. Fences and walls must be properly anchored so as not to be in danger of failure or collapse. |
Outstanding Inspections
Case Number: T11DV06930
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 4
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/29/2011 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | JHURD | Follow-up inspection | 2nd ReInspection Fee Applied |
| 12/29/2011 | NPO(PL)-PLUMBING SYSTEM & FX | JHURD | Follow-up inspection | 2nd ReInspection Fee Applied |
| 12/29/2011 | NPO(DL)-DILAPIDATED STRUCTURE | JHURD | Follow-up inspection | 2nd ReInspection Fee Applied |
| 12/29/2011 | NPO - REFUSE/TRASH/DEBRIS | JHURD | Follow-up inspection | 2nd ReInspection Fee Applied |
Completed Inspections
Case Status: COMPLIAN
Case Number: T11DV06930
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/30/2011 | INSP - INITIAL CODE ENFORCMENT | JHURD | Approved | VISITED SITE: ELECTRICAL SERVICE PANEL DOUBLE LUGGED ON SEVERAL BREAKERS, INTERIOR HAS RESIDUE, DRY TREE PARTS NEEDS CLEANING. INTERIOR: 3 GANG SWITCH COVER PLATE ON 4 GANG BOX. CONVENIENCE OUTLET LACKS COVER PLATE. SQUIRELL CAGE BLOWER HAZARDOUSLY WIRED. HOT WATER TANK: OPEN EXPOSED ROMEX WIRING. WIRED FROM CONVENIENCE OUTLET. LACKS REQUIRED COLD WATER EMERGENCY SHOT OFF VALVE. PERMIT. TRASH/DEBRIS SCATTERED ABOUT AROUND TRASH CONTAINER. WOOD SLATTED FENCE MISSING SLATS. PERMIT REQUIRED FOR HOT WATER TANK. AND ELECTRICAL ISSUES. N/O/V 30 DAYS. |
| 12/29/2011 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Approved | VISITED SITE: EXTERIOR ELECTRICAL SERVICE PANEL UPGRADED 200 AMP. PERMIT T11EL03036 SECURED AND FINALED. ELECTRIC ISSUES ON INTERIOR OF BUILDING NOT ADDRESSED. NON-COMPLIANT ON INTERIOR ISSUES. SEE COND. |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T11DV06930
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
| Date | Name |
| 09/12/2011 | CONTACTED BY MAILING |
| 09/12/2011 | NOTICE OF VIOLATION ISSUED |
| 04/30/2012 | VIOLATION CLOSED |
| 10/17/2011 | REINSPECTION FEE - FIRST |
| 12/30/2011 | REINSPECTION FEE - SECOND |
| 07/17/2012 | REINSP LETTER SENT |