Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T11DV05414
Case Details
Entered Date:
07/18/2011
Applicant:
JOE & LORI LILLY
Description:
#15 - Hot water is leaking in bathroom. Plumber went our but never went back. ceiling falling in. various other violations.
Case Violations
Case Number: T11DV05414
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 7
| Violation Date | Code Statue |
|---|---|
| 07/28/2011 | T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced. |
| 07/28/2011 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
| 07/28/2011 | T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. |
| 07/28/2011 | T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition. |
| 07/28/2011 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 07/28/2011 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 07/28/2011 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
Outstanding Inspections
Case Number: T11DV05414
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/29/2011 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | JHURD | Follow-up inspection | |
| 12/29/2011 | NPO(PL)-PLUMBING SYSTEM & FX | JHURD | Follow-up inspection | |
| 12/29/2011 | NPO(HC)-HEATING & VENTILATION | JHURD | Follow-up inspection | |
| 12/29/2011 | NPO - WORK WITHOUT PERMIT | JHURD | Follow-up inspection | |
| 12/29/2011 | NPO - INT. BUILDING MAINTENANC | JHURD | Follow-up inspection |
Completed Inspections
Case Status: COMPLIAN
Case Number: T11DV05414
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/25/2011 | INSP - INITIAL CODE ENFORCMENT | JHURD | Approved | VISITED SITE: MET W/ OCCUPANT. INTERIOR SHOWS ROOF/CEILING LEAKS. INTERIOR WALL COVERING DAMAGED, DETERIORATED. WALL COVERING NOT COMPLETE TO CEILING USING RAGS TO FILL OPEN HOLE. FLOOR: LIVING ROOM PAINTED SUB-FLOOR WOOD, SEALING ISSUES. (PROTECTANT) TRANSIENT STRIP LACKING BETWEEN VYNIL FLOORING AND WOOD SUB-FLOOR. PERMANENT SOURCE OF HEAT, LACKS REQUIRED FRONT COVER. INTERIOR OF HEATER FIRE HAZARD, LINT, DIRT, DUST. LACKS ANY AND ALL REQUIRED MAINTENANCE. HOLE IN FLOOR. ALLOWS FOR EXTERIOR ELEMENTS TO ENTER LIVING SPACE. TUB/SHOWER LACKS REQUIRED COLD WATER VALVE HANDLE. TUB CONTINUOUSLY LEAKS WATER. BEDROOM LIGHT FIXTURE SHOWS BURN MARKS, CORD HAZARDOUSLY SPLICED. LIGHT FIXTURE 2ND BEDROOM SHOWS BURNT MARKS. LIGHT SWITCH DOES NOT OPERATE. CONVENIENCE OUTLETS, LIGHT SWITCHES THROUGHOUT UNIT DOES NOT OPERATE AS INTENDED. HOT WATER HEATER ROOM LACKS EXTERIOR DOOR. A/C UNIT INSTALLED. NEW DISCONNECT BOX, WIRING INSTALLED. NO PERMITS. RESEARCH P.P. FOR PERMIT ON INSTALLATION OF MOBILE HOME. |
| 12/29/2011 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Approved | VISITED SITE: REQUIRES INTERIOR INSPECTION. FOLLOW UP 30 DAYS. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T11DV05414
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
| Date | Name |
| 08/19/2011 | CONTACTED IN PERSON |
| 08/10/2011 | CONTACTED BY MAILING |
| 08/10/2011 | NOTICE OF VIOLATION ISSUED |
| 10/12/2012 | VIOLATION CLOSED |
| 09/15/2011 | REINSPECTION FEE - FIRST |
| 04/26/2012 | REINSPECTION FEE - SECOND |