Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

05/10/2011

Applicant:

CHARETTE SUSAN REVOC LIFETIME TR

Description:

DESERT SANDS #G OCCUPANT HAS BEEN TRYING TO WORK WITH MANAGER SINCE HE MOVED IN 8 MONTHS AGO TO NO AVAIL. HOT WATER HEATER INSTALLED INCORRECTLY (UNSAFE) W/OUT PERMIT, DAMAGE FROM PREVIOUS SWAMP COOLER LEAK TO FLOOR AND CEILING UNREPAIRED, WINDOWS ARE SCREWED SHUT W/OUT HANDLES, BATHROOM SINK FAUCET LOOSE, SHOWER WALLS WEAK, INOPERABLE SMOKE DETECTOR.

Case Violations

Case Number: T11DV03395
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 7
Violation Date Code Statue
05/12/2011 T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced.
05/12/2011 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
05/12/2011 T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability.
05/12/2011 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
05/12/2011 T.C. Ch. 16, Sec. 16-11(f)(2) Every ceiling, roof, and ceiling and roof support must be sufficient to carry imposed loads safely, and must not buckle, sag or split due to defective material or deterioration.
05/12/2011 T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons.
05/12/2011 T.C. Ch. 16, Sec. 16-14(b)(3) ABATEMENT OF VACANT AND UNSECURED BUILDINGS. When ordered abated, a vacant and unsecured building shall be cleaned and secured as follows: a. All accumulated refuse that poses a fire or health hazard within or upon the property or premises shall be removed; and b. All unsecured doorway, windows, or exterior openings shall be barricaded in accordance with standards established by the code official, which shall be kept on file with the city clerk, and in accordance with section 16-12(a)(3) of this chapter; and c. Both the structure and the exterior premises shall be posted with signs that provide reasonable notice prohibiting entry (i.e., "No Trespassing" signs).

Outstanding Inspections

Case Number: T11DV03395
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 11
End Date Description Inspector Results Comments
06/15/2011 NPO(EL)-MAIN/PANEL/SUB/DISCONT WNAVARRO Item closed
06/15/2011 NPO(EL)-WIRING/SWITCH/OUTLT/FX WNAVARRO Item closed
06/15/2011 NPO(PL)-PLUMBING SYSTEM & FX WNAVARRO Item closed
06/15/2011 NPO(PL)-WATER HEATERS WNAVARRO Item closed
06/15/2011 NPO(HC)-COOLING WNAVARRO Item closed
06/15/2011 NPO(HC)-NO VENTILATION WNAVARRO Item closed
06/15/2011 NPO(DL)-VACANT & UNSEC.STRUCT WNAVARRO Item closed
06/15/2011 NPO - EXT. HAZ/ATTRACT NUISANC WNAVARRO Item closed
06/15/2011 NPO - EXT. BUILDING MAINTENANC WNAVARRO Item closed
06/15/2011 NPO - WORK WITHOUT PERMIT WNAVARRO Item closed
06/15/2011 NPO - INT. BUILDING MAINTENANC WNAVARRO Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T11DV03395
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/10/2011 INSP - INITIAL CODE ENFORCMENT WNAVARRO Approved VISIED SITE, INSPECTED, FOUND MISSING FLOOR TILES THRU OUT THE UNIT,ELECTRICAL OUTLETS ARE MISSING COVER PLATES,EXHAUST COVER FOR SWAMP COOLER MISSING, CEILING IS DETERIORATED AROUND SWAMP COOLER AREA, INSECT INFESTATION IN UNIT, NO GROUND FAULT INTERRUPTER AROUND KITCHEN AREA, BATHTUB SEAL IS DETERRIORATED AND IS DAMAGING WALLS, BATHROOM FAUCET IS MISSING A HANDLE, WATER HEATER WAS INSTALLED WITH OUT A PERMIT, SWAMP COOLER NEEDS MAINTAINENCE, MET WITH MANAGER, DISCUSSED TAHT HE IS TO RECIEVE A NOTICE OF VIOLATION AND THE PROCESS, TIME LINES, EXTENSIONS, REINSPECTION FEES, CITATIONS, GAVE THIRTY DAYS AND FOLLOW UP TO BE ON 06/10/2011
06/15/2011 INSP - FOLLOW UP CODE ENFORCE WNAVARRO Approved VISITED INSPECTED, FOUND ALL VIOLATIONA ABATED, CASE CLOSED- ABATED

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T11DV03395
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
05/16/2011 CONTACTED BY MAILING
05/16/2011 NOTICE OF VIOLATION ISSUED
06/20/2011 VIOLATION CLOSED

Documents

File Name Document Type  
T11DV03395.PDF DOCUMENTS VIEW
None IMAGES VIEW