Case Details

Status:

COMPLIAN

Type:

WORK WITHOUT PERMITS-RESIDENTL

Entered Date:

05/09/2011

Applicant:

DIANE H. LOPEZ & JASON AARON LOPEZ

Description:

Built structure in backyard w/o permits.

Case Violations

Case Number: T11DV03361
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Violations: 1
Violation Date Code Statue
06/06/2011 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Outstanding Inspections

Case Number: T11DV03361
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
12/06/2011 NPO - WORK WITHOUT PERMIT JVALDEZ Extension granted

Completed Inspections

Case Status: COMPLIAN
Case Number: T11DV03361
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/24/2011 INSP - INITIAL CODE ENFORCMENT JVALDEZ Approved SITE INSPECTION RESULTS: SUPERVISOR AND INSPECTOR VIDAL AND OWNER PRESENT. REAR 10 X 32 ADDITION WOOD FRAME CONSTRUCTED WITHOUT PERMITS. THE ADDITION IS ATTACHED TO THE SLUMP BLOCK HOME. THE ADDITION DOES HAVE 3 COMPARTMENTS TWO STORAGE ROOMS WITH A LAUNDRY ROOM IN THE CENTER. THE INTERIOR OF THE ROOMS ARE A FINISH STATE ( DRYWALL). THE CENTER ROOM HAS WASHING MACHINE UNDER THE SERVICE EQUIPMENT. THE SERVICE EQUIPMENT HAS TWO NEW CIRCUITS (ROMEX) 12/2 TO UNKNOWN AND 10/2 TO DRYER. CABLES ARE STAPLED TO THE DRYWALL. THE SERVICE EQUIPMENT IS NOW HOUSED INSIDE THE ADDITION. I HAVE ALERTED DSD AND TEP FOR DIRECTION. ADVISED OWNER TO HAVE PLANS DRAWN UP FOR THE ADDITION. THERE IS A NEW CMU PERIMETER WALL OVER 6 FT IN HEIGHT. RESEARCHING CASE MORE INFORMATION AT THIS TIME, SUPERVISOR IS ON BOARD WITH DIRECTION OF CASE.
12/06/2011 INSP - FOLLOW UP CODE ENFORCE JVALDEZ Approved SCHEDULE A 30 DAY FOLLOW UP INSPECTION

Outstanding Case Activity Conditions

Date Name Approved
06/07/2011 2006 INTERNATIONAL RESIDENTIAL CODE CHAPTER 33 GENERAL REQUIREMENTS SECTION E3305.2 WORKING CLEARANCES FOR ENERGIZED EQUIPMENT AND PANEL BOARDS. EXCEPT AS OTHERWISE SPECIFIED IN CHAPTERS 33 THROUGH 42, THE DIMENSION OF THE WORKING SPACE IN THE DIRECTION OF ACCESS TO PANELBOARDS AND LIVE PARTS LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING OR MAINTENANCE WHILE ENERGIZED SHALL BE NOT LESS THAN 36 INCHES (914 MM) IN DEPTH. DISTANCES SHALL BE MEASURED FROM THE ENERGIZED PARTS WHERE SUCH PARTS ARE EXPOSED OR FROM THE ENCLOSURE FRONT OR OPENING WHERE SUCH PARTS ARE ENCLOSED. IN ADDITION TO THE 36-INCH DIMENSION (914 MM), THE WORK SPACE SHALL NOT BE LESS THAN 30 INCHES (762 MM) WIDE IN FRONT OF THE ELECTRICAL EQUIPMENT AND NOT LESS THAN THE WIDTH OF SUCH EQUIPMENT. THE WORK SPACE SHALL BE CLEAR AND SHALL EXTEND FROM THE FLOOR OR PLATFORM TO A HEIGHT OF 6.5 FEET (1981 MM). IN ALL CASES, THE WORK SPACE SHALL ALLOW AT LEAST A 90-DEGREE OPENING OF EQUIPMENT DOORS OR HINGED PANELS. EQUIPMENT ASSOCIATED WITH THE ELECTRICAL INSTALLATION LOCATED ABOVE OR BELOW THE ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO EXTEND NOT MORE THAN 6 INCHES (152 MM) BEYOND THE FRONT OF THE ELECTRICAL EQUIPMENT. Not Approved

Completed Activity Special Conditions

Case Description - WORK WITHOUT PERMITS-RESIDENTL
Case Number - T11DV03361
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 11
Date Name
05/26/2011 CONTACTED BY PHONE
06/06/2011 CONTACTED IN PERSON
06/08/2011 CONTACTED BY MAILING
06/06/2011 CONTACTED BY EMAIL
03/22/2012 CERTIFIED RECEIPT CARD
06/08/2011 NOTICE OF VIOLATION ISSUED
03/06/2012 CITATION ISSUED
04/16/2013 VIOLATION CLOSED
03/08/2012 COURT HEARING INFO
06/06/2011 RESEARCH
03/09/2012 REINSPECTION FEE - FIRST