Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

05/04/2011

Applicant:

RAYMOND W. GOBEA

Description:

RMIN: Broken windows, no cooling, boiler/water heater does not work (no hot water). Has reported to Owner previously. *Note: Inspector please contact Occupant to ensure entry prior to going onsite **

Case Violations

Case Number: T11DV03170
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
Violation Date Code Statue
05/17/2011 T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced.
05/17/2011 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
05/17/2011 T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability.
05/17/2011 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
05/17/2011 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.

Outstanding Inspections

Case Number: T11DV03170
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
08/26/2011 NPO(PL)-WATER HEATERS JVALDEZ Follow-up inspection
08/26/2011 NPO(HC)-COOLING JVALDEZ Follow-up inspection
08/26/2011 NPO - INT. BUILDING MAINTENANC JVALDEZ Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T11DV03170
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/11/2011 INSP - INITIAL CODE ENFORCMENT JVALDEZ Approved ON SITE INSPECTION RESULTS: INTERIOR OF HOME HAS DAMAGED FLOOR TILES. THE BEDROOM HAS DAMAGED FLOOR STEP. BOTH BEDROOMS HAVE BROKEN WINDOWS. KITCHEN HAS VENT OPENING ABOVE STOVE THAT IS NOT PROPERLY SEALED. OUTLET BOX NOT PROPERLY INSTALLED IN THE KITCHEN AREA WALL. ELECTRIC WATER HEATER IS INOPERABLE AND NOT PROPERLY INSTALLED, MISSING DISCHARGE PIPE. NO COVER PLATE ON THE OUTLET BOX WITH WATER HEATER CONDUCTORS. EVAPORATIVE COOLER IS INOPERABLE, WALL FURNACE IS INOPERABLE. BEDROOM WALL MOUNTED AIR CONDITION UNIT HAS OUTLET BOX UNSECURED AND NEW ROMEX CABLE INSTALLED.
08/26/2011 INSP - FOLLOW UP CODE ENFORCE JVALDEZ Approved TENANTS HAVE MOVED OUT, PERMIT IS STILL IN ACTIVE STATUS UNTIL 01/02/2012 , NO INSPECTIONS HAVE BEEN CALLED FOR. WILL CONTACT OWNER.

Outstanding Case Activity Conditions

Date Name Approved
05/17/2011 T.C. CH 16 Sec 16-11 (f) (5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. T.C. CH 16 Sec 16-11 (f) (6) All repair work shall be done in a workman like manner. Not Approved

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T11DV03170
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
05/17/2011 CONTACTED BY PHONE
05/17/2011 CONTACTED BY MAILING
05/17/2011 NOTICE OF VIOLATION ISSUED
05/17/2012 VIOLATION CLOSED
06/27/2011 REINSPECTION FEE - FIRST
11/01/2011 REINSP FEE - PAID IN FULL