Case: T11DV02916
Case Details
Entered Date:
04/25/2011
Applicant:
CARAVANS VII LLC
Description:
SPACE #109 NO SMOKE DETECTORS, MISSING WINDOW, UNSECURE REAR DOOR, HOLE IN FLOOR, WEAK FLOORING, SHOWER NOT WORKING PROPERLY, BATH TUB CONTINUOUSLY LEAKS, HEAT AND STOVE RECENTLY SWITCHED FROM NATURAL GAS TO PROPANE INCORRECTLY ACCORDINGLY TO MAINTENANCE.
Case Violations
Case Number: T11DV02916
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
| Violation Date | Code Statue |
|---|---|
| 04/28/2011 | T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. |
| 05/09/2011 | T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition. |
| 05/09/2011 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
| 05/09/2011 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 05/09/2011 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 05/09/2011 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
Outstanding Inspections
Case Number: T11DV02916
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 8
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/28/2011 | NPO(HC)-HEATING & VENTILATION | JHURD | Item closed | |
| 04/28/2011 | NPO - WORK WITHOUT PERMIT | JHURD | Item closed | |
| 07/18/2011 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | JHURD | Item closed | |
| 07/18/2011 | NPO(PL)-PLUMBING SYSTEM & FX | JHURD | Item closed | |
| 07/18/2011 | NPO(PL)-GAS SUPPLY/CONNECT | JHURD | Item closed | |
| 07/18/2011 | NPO - SMOKE ALARMS | JHURD | Item closed | |
| 07/18/2011 | NPO - EXT. BUILDING MAINTENANC | JHURD | Item closed | |
| 07/18/2011 | NPO - INT. BUILDING MAINTENANC | JHURD | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T11DV02916
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/26/2011 | INSP - INITIAL CODE ENFORCMENT | JHURD | Approved | VISITED SITE: MET W/OCCUPANT, SHOWED ISSUES. HOLE IN LIVING ROOM FLOOR. KITCHEN WINDOW PLEXI GLASS, WINDOW NOT SEALED TO PROTECT FROM EXTERIOR ELEMENTS. CONVENIENCE OUTLETS MISSING PROTECTIVE COVER. DWELLING LACKS REQUIRED SMOKE DETECTOR. REAR DOOR DOES NOT PROPERLY SEAL TO PROTECT FROM EXTERIOR ELEMENTS. BATH/SHOWER DIVERTER LEAKS. MOBILE HOME PARK CONVERTING FROM NATURAL GAS SYSTEM TO L.P. SYSTEM. NEW L.P. TANK INSTALLED, SITS DIRECTLY ON GROUND, OPENING UNDER MOBILE HOME WITHIN 3' BOTTOM OF MOBILE HOME ENCLOSED. NOT 50% OPENED. LESS THAN 10' FROM NEIGHBOR DRIVEWAY. OCCUPANT STATES REGULATORS/ORIFICES NOT CHANGED OUT. (RESEARCH) |
| 07/18/2011 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Approved | VISITED SITE: TALKED WITH OCCUPANT JOHN, STATED YES MANAGEMENT HAS MADE ALL REPAIRS. COMPLIANT. CLOSE.CASE. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T11DV02916
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 05/09/2011 | CONTACTED BY PHONE |
| 05/18/2011 | CONTACTED BY MAILING |
| 05/02/2011 | CONTACTED BY EMAIL |
| 05/18/2011 | NOTICE OF VIOLATION ISSUED |
| 07/20/2011 | VIOLATION CLOSED |