Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COURTNCM

Type:

EMERGENCY
Address:

Entered Date:

04/25/2011

Applicant:

TYLER B JEFFREY

Description:

TPD call-out for No Electric (CE15 Area). 7/19/11: Bee hive on property near swamp cooler on 1st floor.

Case Violations

Case Number: T11DV02900
Case Status: COURTNCM
Case Description: EMERGENCY
Total Violations: 2
Violation Date Code Statue
04/16/2012 T.C. Ch. 16, Sec. 16-14(b)(3) ABATEMENT OF VACANT AND UNSECURED BUILDINGS. When ordered abated, a vacant and unsecured building shall be cleaned and secured as follows: a. All accumulated refuse that poses a fire or health hazard within or upon the property or premises shall be removed; and b. All unsecured doorway, windows, or exterior openings shall be barricaded in accordance with standards established by the code official, which shall be kept on file with the city clerk, and in accordance with section 16-12(a)(3) of this chapter; and c. Both the structure and the exterior premises shall be posted with signs that provide reasonable notice prohibiting entry (i.e., "No Trespassing" signs).
04/16/2012 T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition.

Outstanding Inspections

Case Number: T11DV02900
Case Status: COURTNCM
Case Description: EMERGENCY
Total Outstanding Inspections - 11
End Date Description Inspector Results Comments
10/28/2011 NPO(EL)-MAIN/PANEL/SUB/DISCONT LPUMPHRE Citation
10/28/2011 NPO(EL)-WIRING/SWITCH/OUTLT/FX LPUMPHRE Citation
10/28/2011 NPO(PL)-PLUMBING SYSTEM & FX LPUMPHRE Citation
10/28/2011 NPO(PL)-WATER HEATERS LPUMPHRE Citation
10/28/2011 NPO(HC)-HEATING & VENTILATION LPUMPHRE Citation
10/28/2011 NPO - INSECTS/PESTS LPUMPHRE Citation
10/28/2011 NPO - EGRESS LPUMPHRE Citation
10/28/2011 NPO - REFUSE/TRASH/DEBRIS LPUMPHRE Citation
10/28/2011 NPO - EXT. BUILDING MAINTENANC LPUMPHRE Citation
10/28/2011 NPO - WORK WITHOUT PERMIT LPUMPHRE Citation
10/28/2011 NPO - INT. BUILDING MAINTENANC LPUMPHRE Citation

Completed Inspections

Case Status: COURTNCM
Case Number: T11DV02900
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/25/2011 INSP - INITIAL CODE ENFORCMENT JHURD Approved EMERGENCY CALL OUT- T.P.D. NO ELECT. LIVING COND. VISITED SITE. 2 STORY DUPLEX. TOP UNIT VACANT. BOTTOM UNIT OCC. NO ELECT. RUNNING 14 AWG EXTENSION CORD FROM NEIGHBOR. SEVERAL DIFFERENT ELECT. CONNECTIONS FROM EXTENSION CORD. MAIN SERVICE BOX FALLING OFF WALL. MAIN SERVICE BOX DOUBLE LUGGED ON LEGS. TRIPLE LUGGED ON NETURAL. NEW ROMEX ADDED, EXPOSED. RAN THROUGH DOOR FRAME. DWELLING LACKS REQUIRED FRONT DOOR. WATER LEAK AT MAIN SUPPLY COOLER LINE. HOT WATER TANK LACKS COLD WATER EMERGENCEY SHUT OFF. LACKS PRESSURE RELIEF VALVE DRAIN LINE. HOT WATER TANK ENCLOSER FULL DRIED WEEDS. (GAS FIRED). STAIR CASE FULL OF TRASH/DEBRIS, STORAGE. DOG FECIES SCATTERED ABOUT REAR YARD. INTERIOR PERMANENT HEAT SOURE DOES NOT OPERATE, OCCUPANT RESORTED TO GAS FIRED OVEN AND SPACE HEATER. BEDROOM EGRESS WINDOW COVERED BY BREAK AWAY SECURITY BARS, BREAK AWAY HANDLE BROKEN, NEEDS TOOL TO OPEN. WATER SUPPLY LINES REPLACED FROM ORIGINAL. EXPOSED ON WALL, RUNS THROUGH WALLS. LACKS ALL PROPER BRACING. BATHROOM LACKS REQUIRED DOOR AND ALL HARDWARE. SHOWER ENCLOSER SHOWS MAJOR CHIPPING OF PROTECTANT, CRACKING. PLUMBING IN CLOSET OFF KITCHEN REDONE, EXPOSED PIPING. 2ND FLOOR BALCONY BEAM, STRENGHT AND STABILITY HAS BEEN COMPERMISED. BEAM HAS FALLEN IN MIDDLE. RAILINGS NO LONGER CONNECTED TO DECKING DUE TO SAGGING OF BEAM. STRUCTURE CONDEMED DUE TO HAZARDOUS ELECT. SYSTEM. NO ELECT. TO UNIT. VACATED AND SECURED @ THIS TIME. N/O/V FOR ALL OTHER ISSUES TO SENT. RELEASED FILE TO AREA INSP. (LAURIE)
10/03/2011 INSP - FOLLOW UP CODE ENFORCE LPUMPHRE Approved No compliance; no permits.

Outstanding Case Activity Conditions

Date Name Approved
04/27/2011 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. Not Approved
04/27/2011 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. Not Approved
04/27/2011 T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition. Not Approved
04/27/2011 T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. Not Approved
04/27/2011 T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools. Not Approved
04/27/2011 T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced. Not Approved
04/27/2011 T.C. Ch. 16, Sec. 16-11(g) INTERIOR SANITATION. (1) The interior of every building or structure shall be maintained free from any unsafe or unsanitary accumulation of refuse. (2) All sanitary facilities shall be installed and maintained in a safe and sanitary condition. (3) Every dwelling unit must have a kitchen, which shall include a sink. Sink drain boards and countertops adjacent to the kitchen sink shall be made of non-absorbent materials, or must be covered by a non-absorbent material. Not Approved
04/27/2011 T.C. Ch. 16, Sec. 16-14(c) BUILDINGS AND STRUCTURES CONSTITUTING A NUISANCE. All buildings and structures are to be maintained so as not to pose a threat to the health and safety of any person or persons. The condition of a building or structure that meets any or all of the following is a public nuisance, is a violation of this chapter, and subjects the building or structure to abatement as provided in Article VI of this chapter, including demolition as provided in section 16-65: (5) The building, structure, or any portion or member or appurtenance thereof is likely to fail, or to become detached or dislodged, or to partially or completely collapse and thereby injure persons or damage property. Not Approved

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T11DV02900
Case Status: COURTNCM
Total Completed Case Activity Conditions: 12
Date Name
05/26/2011 CONTACTED BY PHONE
10/28/2011 CONTACTED BY MAILING
11/21/2011 CERTIFIED RECEIPT CARD
04/27/2011 NOTICE OF VIOLATION ISSUED
10/28/2011 CITATION ISSUED
10/02/2012 VIOLATION CLOSED
08/14/2012 SEC LEIN PLACED ON PROPERTY IN THE AMOUNT OF ???
08/13/2013 SEC LEIN RELEASED ON PROPERTY
10/28/2011 COURT HEARING INFO
10/21/2011 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS
07/27/2011 CONTRACTOR ABATEMENT
08/26/2011 RESEARCH

Documents

File Name Document Type  
CITATION 6884795.PDF DOCUMENTS VIEW
CERTIFIED RECEIPT.PDF DOCUMENTS VIEW