Case: T11DV02096
Case Details
Entered Date:
03/31/2011
Applicant:
YVETTE REDONDO ( MANAGER )
Description:
WATER PIPE BURST
Case Violations
Case Number: T11DV02096
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Violations: 1
| Violation Date | Code Statue |
|---|---|
| 03/31/2011 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
Outstanding Inspections
Case Number: T11DV02096
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/01/2011 | NPO(PL)-PLUMBING SYSTEM & FX | GPETZ | Item closed | |
| 04/01/2011 | NPO(DL)-DILAPIDATED STRUCTURE | GPETZ | Follow-up inspection |
Completed Inspections
Case Status: COMPLIAN
Case Number: T11DV02096
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/30/2011 | INSP - INITIAL CODE ENFORCMENT | JVALDEZ | Approved | EMERGENCY CALL BY TFD, ON SITE INSPECTION RESULTS: BROKEN WATER SUPPLY LINE TO UNIT 380'S WATER HEATER. ON SITE PLUMBER DID CAP THE SUPPLY LINES. I WAS UNABLE TO CONTACT THE MANAGER OR EMERGENCY MAINTENANCE. TFD STATED THE SHUT OFF TO THE BUILDING DID NOT WORK. THE PLUMBER DID SHUT THE WATER OFF FROM THE BACK FLOW DEVICE TO MAKE REPAIRS. THERE WAS WATER THAT PENETRATED THE INTERIOR OF UNITS 280 AND 180. UNIT 380 WAS LOCKED UNABLE TO INSPECT. UNIT 280'S IRON FENCE GUARD IS MISSING HARDWARE AND IS LOOSE. |
| 04/01/2011 | INSP - FOLLOW UP CODE ENFORCE | GPETZ | Approved | Emergency violations abated. Close case. GP |
Outstanding Case Activity Conditions
| Date | Name | Approved |
| 03/31/2011 | 2006 INTERNATIONAL BUILDING CODE CHAPTER 16 - STRUCTURAL DESIGN 1607.7.1 HANDRAILS AND GUARDS. HANDRAIL ASSEMBLIES AND GUARDS SHALL BE DESIGNED TO RESIST A LOAD OF 50 PLF (0.73 KN/M) APPLIED IN ANY DIRECTION AT THE TOP AND TO TRANSFER THIS LOAD THROUGH THE SUPPORTS TO THE STRUCTURE. GLASS HANDRAIL ASSEMBLIES AND GUARDS SHALL ALSO COMPLY WITH SECTION 2407. EXCEPTIONS: 1. FOR ONE- AND TWO-FAMILY DWELLINGS, ONLY THE SINGLE CONCENTRATED LOAD REQUIRED BY SECTION 1607.7.1.1 SHALL BE APPLIED. 1607.7.1.1 CONCENTRATED LOAD. HANDRAIL ASSEMBLIES AND GUARDS SHALL BE ABLE TO RESIST A SINGLE CONCENTRATED LOAD OF 200 POUNDS (0.89 KN), APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP, AND HAVE ATTACHMENT DEVICES AND SUPPORTING STRUCTURE TO TRANSFER THIS LOADING TO APPROPRIATE STRUCTURAL ELEMENTS OF THE BUILDING. THIS LOAD NEED NOT BE ASSUMED TO ACT CONCURRENTLY WITH THE LOADS SPECIFIED IN THE PRECEDING PARAGRAPH. 2. IN GROUP I-3, F, H AND S OCCUPANCIES, FOR AREAS THAT ARE NOT ACCESSIBLE TO THE GENERAL PUBLIC AND THAT HAVE AN OCCUPANT LOAD LESS THAN 50, THE MINIMUM LOAD SHALL BE 20 POUNDS PER FOOT (0.29 KN/M). | Not Approved |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T11DV02096
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 03/31/2011 | CONTACTED IN PERSON |
| 04/01/2011 | VIOLATION CLOSED |
| 03/31/2011 | CALLBACK |