Case: T11DV01965
Case Details
Entered Date:
03/28/2011
Applicant:
ANDRADE SERGIO
Description:
FIRE DAMGE
Outstanding Inspections
Case Number: T11DV01965
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 4
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/27/2011 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | LPUMPHRE | Item closed | |
| 07/27/2011 | NPO(DL)-DILAPIDATED STRUCTURE | LPUMPHRE | Item closed | |
| 07/27/2011 | NPO - REFUSE/TRASH/DEBRIS | LPUMPHRE | Item closed | |
| 07/27/2011 | NPO - JUNKED/INOP. VEHICLE(S) | LPUMPHRE | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T11DV01965
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/27/2011 | INSP - INITIAL CODE ENFORCMENT | JVALDEZ | Approved | EMERGENCY CALL OUT BY TFD, A DETACHED WORKSHOP AND CARPORT LOCATED IN THE BACKYARD AREA WERE DAMAGED BY FIRE. THE WORKSHOP IS DIMENSIONED AT 160 SQUARE FEET FIRE DAMAGE WAS IN THE INTERIOR SOUTH FACE OF THE WOOD FRAMED WITH METAL SHEATHING BUILDING. THE BUILDING DID HAVE ELECTRICAL. WIRING WAS BURNT ALONE WITH LIGHTING FIXTURES AND WALL RECEPTACLES. THE CARPORT WHICH ID ATTACHED TO THE WORKSHOP IS DIMENSIONED AT 168 SQ FEET THE RAFTERS AND POST HAVE ¼ TO ½ CHARRED CRACKS IN THE LUMBER. THE ROOF IS METAL CORRUGATED STEEL PANELS WHICH HAVE HEAT DAMAGE. THE ENTIRE STRUCTURE IS ONE AND PERMITS ARE REQUIRED TO DEMOLISH THE STRUCTURE. I ADVISED THE OWNER STRUCTURE WHICH EXCEED 120 SQ FEET REQUIRE BUILDING PERMITS. THE 20 AMP CIRCUIT BREAKER WAS SHUT OFF AT THE PANEL BOARD LOCATED REAR OF THE MAIN HOUSE. I ADVISED THE OWNER TO DISCONNECT THE CIRCUIT. 3 VEHICLES WERE DAMAGE AS A RESULT OF THE FIRE 1, DODGE RV 1, WHITE HYUNDAI, 1 ISUZU AMIGO. ALL VEHICLES ARE JUNK MOTOR VEHICLES AND MUST BE REMOVED FROM THE PROPERTY OR MEET EXCEPTIONS OF THE CODE. ALL TRASH AN DEBRIS MUST BE REMOVED FROM THE SITE WITHIN 60 DAYS. SCHEDULE A 60 DAY FOLLOW UP INSPECTION TO THE AREA INSPECTOR |
| 07/27/2011 | INSP - FOLLOW UP CODE ENFORCE | LPUMPHRE | Approved | Compliant; vehicles, refuse, and building removed. Owner will need permit to rebuild another structure. |
Completed Activity Special Conditions
Case Description - RESIDENTIAL FIRE
Case Number - T11DV01965
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 03/28/2011 | CONTACTED IN PERSON |
| 03/28/2011 | CONTACTED BY EMAIL |
| 03/28/2011 | NOTICE OF VIOLATION ISSUED |
| 07/27/2011 | VIOLATION CLOSED |
| 03/28/2011 | CALLBACK |