Case Details

Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

02/07/2011

Applicant:

BARRIGA JUAN CARLOS OCHOA

Description:

COMMUNICATION CALLED AND T.F.D. ON SITE WITH FIRE IN THE BATHROOM, ALARM # 11-07784

Case Violations

Case Number: T11DV00748
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Violations: 4
Violation Date Code Statue
02/11/2011 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
02/11/2011 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
02/11/2011 T.C. Ch. 16, Sec. 16-11(f)(1) Every wall or vertical support must be sufficient to carry imposed loads safely, and must not lean, buckle, or split due to defect or lack of maintenance.
02/11/2011 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Outstanding Inspections

Case Number: T11DV00748
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
07/25/2011 NPO(EL)-MAIN/PANEL/SUB/DISCONT MROMERO Follow-up inspection
07/25/2011 NPO(EL)-WIRING/SWITCH/OUTLT/FX MROMERO Follow-up inspection
07/25/2011 NPO(PL)-PLUMBING SYSTEM & FX MROMERO Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T11DV00748
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
02/05/2011 INSP - INITIAL CODE ENFORCMENT RVIDAL Approved RECEIVED A CALL FROM COMMUNICATION THAT T.F.D ON SITE WITH A BATHROOM FIRE. ARRIVED AND ALL UNITS HAVE CLEARED AND MET THE OWNER AND A FRIEND TO CHECK THE FIRE DAMAGE. ALL POWER WAS OFF AT THE MAIN SERVICE PANEL AT THE EXTERIOR OF THE HOUSE. DID CHECK THE FIRE DAMAGE AND NO ELECTRICAL WAS DAMAGED AND THE POWER WAS RESTORED TO THE HOUSE. THE FIRE DAMAGE WAS IN THE HALL BATHROOM AT THE VANITY WHERE A HAIRDRYER WAS LEFT ON AND STARTED A FIRE ON THE VANITY AND STARTED TO BURN. DURING THE FIRE A SUPPLY LINE MELTED AND PUT THE FIRE OUT. FIRE DEPARTMENT MADE HOLES IN THE WALL TO CHECK FOR FIRE PENATRATION AND FOUND NONE. THERE WAS SMOKE DAMAGE THROUGH OUT BUT IS LIGHT. THE BATHROOM HAS HEAVY SMOKE DAMAGE AND SOME GOING INTO THE HALL. WILL CHECK RECORDS OF THE HOUSE LAYOUT WITH PLANNING AND DEVELOPMENT SERVICES AND TAKE TO THE OWNER. WILL DO N.O.V. AND TAKE TO THE OWNER. RV.
07/25/2011 INSP - FOLLOW UP CODE ENFORCE MROMERO Approved SITE INSPECTION SHOWS NO ONE HOME, PERMIT EXPIRES 1-23-2011, FU 1-24-2012

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T11DV00748
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
06/21/2011 CONTACTED BY PHONE
02/23/2011 NOTICE OF VIOLATION ISSUED
01/25/2012 VIOLATION CLOSED
02/23/2011 8-5 CITY COMM EMERGENCY

Documents

File Name Document Type  
EMER CALL-OUT DOCS 2-5-11.PDF DOCUMENTS VIEW
0510081531.PDF DOCUMENTS VIEW
None IMAGES VIEW