Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

12/03/2010

Applicant:

SABINO-VERDE LLC

Description:

Full inspection done 12/1/2010; Grant Bennett - Owner / 885-2842 / A2 Occupancy / Jason McCarty - Manager /

Completed Inspections

Case Status: COMPLETE
Case Number: T10FR02549
Case Description: INSPECTION
Total Completed Inspections - 4
End Date Description Inspector Results Comments
12/03/2010 VIOL - MEANS OF EGRESS BCOBB Approved Emergency lighting: IFC2006 [with modifications]/ 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: [where currently located] ______Fix all inoperative emergency lights.
12/03/2010 VIOL - FIRE PROTECTION SYSTEMS BCOBB Approved Hood system coverage: 904.11.6 Operations and maintenance. Commercial cooking systems shall be operated and maintained in accordance with this section. ______ Hood system to be checked to make sure the appliances are covered properly.
12/03/2010 VIOL - PRECAUTION AGAINST FIRE BCOBB Approved Clearance below sprinklers: TFC 315.2.1 Ceiling clearance. Storage shall be maintained 24 inches (610 mm) or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches (457 mm) below sprinkler head deflectors in sprinklered areas of buildings. ______Remove storage to 18 inches or more below sprinkler head.
12/03/2010 INSP - FULL BCOBB Approved Please correct the following Tucson Fire Code violations: Notes: 1. C of O to be provided upon re-inspection, if available. If not available, manager will be in the process of acquiring it. Certificate of Occupancy [C of O]: 1997 Uniform Administrative Code Section 309.5 Posting. The certificate of occupancy shall be posted in a conspicuous place on the premises and shall not be removed except by the building official. ______ Acquire a C of O from Developmental Services. [791-5550] ______ C of O on site. 2. A record of the sprinkler system inspections shall be made available upon re-inspection. Sprinkler system: 903.5 Testing and maintenance. Sprinkler systems shall be tested and maintained in accordance with Section 901. _______ System to be tested, and tagged annually. [All deficiencies abated, and a copy of the report to be on the premises]