Case: T10FR02303
Case Details
Entered Date:
11/02/2010
Applicant:
7601-7667 SPEEDWAY TUCSON LLC 25.3658% &
Description:
Full inspection done 11/2/10; "M" occupancy; Lynda Luiten - owner - 747-8458;
Completed Inspections
Case Status: COMPLETE
Case Number: T10FR02303
Case Description: INSPECTION
Total Completed Inspections - 6
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/02/2010 | VIOL - MEANS OF EGRESS | BCOBB | Approved | Exit signs: TFC 1011.1 Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30 480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. ______Place exit signs in an approved manner over the 3 doors and 2 doorways we discussed. Thank you. |
11/02/2010 | VIOL - MEANS OF EGRESS | BCOBB | Approved | Double keyed lock on door: 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. ______ Remove Keyed dead bolt. [classroom door] |
11/02/2010 | VIOL - FIRE PROTECTION SYSTEMS | BCOBB | Approved | Extinguishers not mounted: TFC2006/ 906.9 Height above floor. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of installed hand-held extinguishers shall not be less than 4 inches (102 mm). ______ Mount extinguishers in an approved manner. The ones there now are ok- just out of date. If you choose to install bigger extinguishers, please mount them by the exits. |
11/02/2010 | VIOL - FIRE PROTECTION SYSTEMS | BCOBB | Approved | Extinguishers not tagged / inspected: TFC2006/ 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. ______ Extinguishers shall be maintained, inspected and tagged [annually] in accordance with this code. |
11/02/2010 | VIOL - BUILDING SVCS & SYSTEMS | BCOBB | Approved | Extension cords: TFC2006/ 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. _____ Remove or replace with approved fused power strip. |
11/02/2010 | INSP - FULL | BCOBB | Approved | Please correct the following Tucson Fire Code violations: |