Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

10/25/2010

Applicant:

MARKES NICHOLAS J & MARKES HELEN TR

Description:

Rainbow 10/22/10

Outstanding Inspections

Case Number: T10FR02208
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
10/25/2010 VIOL - BUILDING SVCS & SYSTEMS MPURSLEY Correction Required 605.4.1 Power tap design Relocatable power taps shall be of the polarized or grounded type, equipped with overcurrent protection, and shall be listed in accordance with UL 1363. _____Plug multi-plug adaptors directly into outlets
10/25/2010 VIOL - FIRE RESIST.RATED CONST MPURSLEY Correction Required 703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, fire-stops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire _____ Fix and repair all openings or holes in the ceiling
10/25/2010 VIOL - MEANS OF EGRESS MPURSLEY Correction Required 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. _____ Remove the double-keyed lock and replace with an approved locking device such as, thumb turn lock or panic hardware 1011.1 Exit Signs ____Place "NO EXIT" on confusing doors 1021.2 Width. The width of exit passageways shall be determined as specified in Section 1005.1 but such width shall not be less than 44 inches (1118 mm), except that exit passageways serving an occupant load of less than 50 shall not be less than 36 inches (914 mm) in width. The required width of exit passageways shall be unobstructed. _____Maintain minimum aisle width

Completed Inspections

Case Status: COMPLETE
Case Number: T10FR02208
Case Description: INSPECTION
Total Completed Inspections - 1
End Date Description Inspector Results Comments
12/09/2010 INSP - REINSPECTION MPursley Approved All corrections made 12/7/10