Case: T10FR01968
Case Details
Entered Date:
09/24/2010
Applicant:
BROADWAY-CRAYCROFT LLC
Description:
Full Inspection conducted 09/24/10 I have received a copy of this report and understand the corrections needed: ______________ Business Rep.: Kiara Carreon Phone: 790-5550 Inspector: _________________, David Greenleaf, MA 23 If you have any questions please call 791-4502. Approved: ________ Re-inspection: 10/8/10 (or after) Certificate of Occupancy: POSTED, OL=43 NOTE: Partial protection sprinkler system System NOT inspected, NO FDC Hood tagged 9/10, by Anozira 622-1010 Provide and retain copies of system inspection reports. Please correct the following Tucson Fire Code violations:
Outstanding Inspections
Case Number: T10FR01968
Case Status: FIELD
Case Description: INSPECTION
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/24/2010 | INSP - FULL | dgreenl1 | Violation | Full Inspection conducted 09/24/10 I have received a copy of this report and understand the corrections needed: ______________ Business Rep.: Kiara Carreon Phone: 790-5550 Inspector: _________________, David Greenleaf, MA 23 If you have any questions please call 791-4502. Approved: ________ Re-inspection: 10/8/10 (or after) Certificate of Occupancy: POSTED, OL=43 NOTE: Partial protection sprinkler system System NOT inspected, NO FDC Hood tagged 9/10, by Anozira 622-1010 Provide and retain copies of system inspection reports. Please correct the following Tucson Fire Code violations: TFC 904.11.5 - Commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. _____ Install a Class-K extinguisher. TFC 904.11.6.3 - Cleaning. Hoods, grease-removal devices, fans, ducts and other appurtenances shall be cleaned at intervals necessary to prevent the accumulation of grease. Cleanings shall be recorded, and records shall state the extent, time and date of cleaning. Such records shall be maintained on the premises. _____ Clean hood system and keep records of periodical cleanings. TFC 605.4.1 - Power tap design. Relocatable power taps shall be of the polarized or grounded type, equipped with overcurrent protection, ***Replace extension cord/power taps with approved power strips. _____ Coffee Pot _____ TV, South Wall Missing or moved ceiling tiles: TFC 703.1 - Maintenance The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. *** Replace missing ceiling tiles _____ Over water heater _____ Storeroom 1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted. _____ Remove bolt lock from back door. 3003.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. _____ Secure all compressed gas tanks even when empty. |