Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

09/01/2010

Applicant:

ALVERNON APARTMENTS LLC

Description:

2625 N. Alvernon Apt.s 8/31/10

Outstanding Inspections

Case Number: T10FR01867
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
09/01/2010 VIOL - FIRE SERVICE FEATURES MPursley Correction Required 505.1 Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. _____Place Address, building, and apartment numbers, that are plainly legible.
09/01/2010 VIOL - FIRE PROTECTION SYSTEMS MPursley Correction Required 907.2.10.1.2 Groups R-2, R-3, R-4 and I-1. Single or multiple-station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4 and I-1regardless of occupant load at all of the following locations: 1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. 2. In each room used for sleeping purposes. 3. In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. _____Maintain smoke detectors in individual units.
09/01/2010 VIOL - MEANS OF EGRESS MPursley Correction Required 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. _____ Remove the pad locks and replace with an approved locking device such as, thumb turn lock on all gates/doors that are part of egress.