Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

08/05/2010

Applicant:

CAVA RICHARD ANTHONY & CAVA ANTHONY

Description:

Taco bell fire inspection.

Outstanding Inspections

Case Number: T10FR01619
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
08/05/2010 VIOL - BUILDING SVCS & SYSTEMS JLOYA Violation 605.4 - Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with the ICC Electrical Code shall be prohibited.
08/05/2010 VIOL - BUILDING SVCS & SYSTEMS JLOYA Violation 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes ___ Cover empty slots at breaker panels.
08/05/2010 VIOL - MEANS OF EGRESS JLOYA Violation 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists:2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background

Completed Inspections

Case Status: COMPLETE
Case Number: T10FR01619
Case Description: INSPECTION
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/05/2010 INSP - FULL JLOYA Approved Correct the following fire code violations found during life/safety fire inspection. Thank you for your cooperation, for any questions please contact inspector Jorge Loya @ 837-7118, Fax 791-5346. Received by_________________ Date__________
08/24/2010 INSP - REINSPECTION JLOYA Approved Violations abated.