Case Details

Status:

COMPLETE

Type:

INSPECTION
Address:

Entered Date:

06/04/2010

Applicant:

LPR PROPERTIES LLC

Description:

Full Fire Prevention Inspection. 292-3484 Nubia Rios

Outstanding Inspections

Case Number: T10FR01092
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
06/04/2010 VIOL - PRECAUTION AGAINST FIRE JBURGE Correction Required IFC 316.2 Clothes dryers. Clothes dryers shall be frequently cleaned to maintain the lint trap and mechanical and heating components free from excessive accumulations of lint. _____1. Clean and remove all lint accumulation from the dryer vents.
06/04/2010 VIOL - BUILDING SVCS & SYSTEMS JBURGE Correction Required IFC 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. _____1. The open space located in the East electrical panel shall be properly covered. NOTE: Remove lint build-up in the panels. ________________________________________________ (John E. Bieg, Fire Inspector, Tucson Fire Department) I, ______________________ have received a copy of this inspection report. (Building Representative) ______________________________ (Captain) Re-inspection scheduled on or after _____/_____/_____ Call Inspector Bieg at 235-4785 or 791-4502, if you have any further questions. All noted Tucson Fire Code violations have been corrected: _____/_____/_____ ______________________ John E. Bieg
06/04/2010 VIOL - MEANS OF EGRESS JBURGE Correction Required 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background, 2.3. The use of the key-operated locking device is revocable by the fire code official for due cause. _____1. Post the wording "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" on the inside of the North door.

Completed Inspections

Case Status: COMPLETE
Case Number: T10FR01092
Case Description: INSPECTION
Total Completed Inspections - 1
End Date Description Inspector Results Comments
07/07/2010 INSP - FULL JBURGE Approved All noted Tucson Fire Code violations have been corrected.