Case: T10FR00401
Case Details
Entered Date:
02/24/2010
Applicant:
DI MARIA JOSEPH M & BARBARA J TR
Description:
Full Inspection conducted 2/23/10 I have received a copy of this report and understand the corrections needed: ______________ Business Rep.: Mike DiMira Phone: 745-8589 Inspector: __________________, Captain: ___________ David Greenleaf, MA 23 If you have any questions please call 791-4502. Approved: ________ Re-inspection: __/__/__ (or after) Certificate of Occupancy: NOT on file Please correct the following Tucson Fire Code violations:
Outstanding Inspections
Case Number: T10FR00401
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/23/2010 | INSP - FULL | dgreenl1 | Violation | TFC 2604.2.6 - Fire extinguisher. (Welding) A minimum of one portable fire extinguisher complying with Section 906 and with a minimum 2-A:20-B:C rating shall be readily accessible within 30 feet (9144 mm) of the location where hot work is performed. TFC 2205.5 - Fire extinguishers. Approved portable fire extinguishers complying with Section 906 with a minimum rating of 2-A:20-B:C shall be provided and located such that an extinguisher is not more than 75 feet from pumps, dispensers or storage tank fill-pipe openings. Chapter 906, Portable Fire Extinguishers TFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. TFC 906.5 - Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. TFC 906.6 - Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of extinguishers. TFC 906.7 - Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. TFC 906.9 - Height above floor. Portable fire extinguishers having a gross weight not exceeding 40 shall be installed so that its top is not more than 5 feet above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds shall be installed so that its top is not more than 3.5 feet above the floor. The clearance between the floor and the bottom of installed hand-held extinguishers shall not be less than 4 inches. _____ Mount extinguisher in an approved manner. TFC 901.6 - Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. _____ Extinguishers shall be inspected by occupant monthly and professionally serviced annually. A tag shall be affixed to the extinguisher with records of these activities. TFC 2703.4 - Material Safety Data Sheets. Material Safety Data Sheets (MSDS) shall be readily available on the premises for hazardous materials regulated by this chapter. When a hazardous substance is developed in a laboratory, available information shall be documented. Exception: Designated hazardous waste. _____ Provide MSDS and training. TFC 2703.5 - Hazard identification signs. Unless otherwise exempted by the fire code official, visible hazard identification signs as specified in NFPA 704 for the specific material contained shall be placed on stationary containers and above-ground tanks and at entrances to locations where hazardous materials are stored, dispensed, used or handled in quantities requiring a permit and at specific entrances and locations designated by the fire code official. _____ Post "Flammable" sign at entrance to rooms containing flammable and combustible liquids. _____ Post "Corrosives" sign at entrance to rooms containing battery storage. TFC 2703.7.1 - Smoking. Smoking shall be prohibited and "No Smoking" signs provided as follows: 1. In rooms or areas where hazardous materials are stored or dispensed or used in open systems in amounts requiring a permit in accordance with Section 2701.5. 2. Within 25 feet (7620 mm) of outdoor storage, dispensing or open use areas. 3. Facilities or areas within facilities that have been designated as totally "no smoking" shall have "No Smoking" signs placed at all entrances to the facility or area. Designated areas within such facilities where smoking is permitted either permanently or temporarily, shall be identified with signs designating that smoking is permitted in these areas only. 4. In rooms or areas where flammable or combustible hazardous materials are stored, dispensed or used. Signs required by this section shall be in English as a primary language or in symbols allowed by this code and shall comply with Section 310. _____ Post "NO SMOKING" signs at entrance to rooms containing flammable and combustible liquids. TFC 1008.1.8 - Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. _____ Replace keyed dead bolt locks with thumb turn mechanisms on egress side of exit doors. 1028.2 Reliability. Required exit accesses, exits or exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency when the areas served by such exits are occupied. Security devices affecting means of egress shall be subject to approval of the fire code official. _____ Keep lockers clear of exit door. _____ keep gate in back unlocked while building is occupied. |
Completed Inspections
Case Status: COMPLETE
Case Number: T10FR00401
Case Description: INSPECTION
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/09/2010 | INSP - REINSPECTION | dgreenl1 | Approved |