Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE

Entered Date:

12/17/2010

Applicant:

DON B. & PATRICIA M. OVERALL

Description:

HOUSE FIRE

Outstanding Inspections

Case Number: T10DV08985
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
12/17/2010 NPO(EL)-MAIN/PANEL/SUB/DISCONT JVALDEZ Item initialized
12/17/2010 NPO(PL)-GAS SUPPLY/CONNECT JVALDEZ Item initialized
12/17/2010 NPO(DL)-DILAPIDATED STRUCTURE JVALDEZ Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T10DV08985
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/16/2010 INSP - INITIAL CODE ENFORCMENT JVALDEZ Approved EMERGENCY CALLED OUT BY TUCSON FIRE DEPT: HOUSE FIRE FRONT BEDROOM SUSTAINED THE MOST DAMAGE. CEILING T1-11 SIDING AND DECO BEAMS HAVE ALLIGATORING AND ARE CHARRED. THE DRYWALL IN THE BEDROOM WALLS HAVE DAMAGED FROM THE WATER. THE HALLWAY SOFFIT AREA HAS PUNCTURE HOLES AND THE METAL DUCT WORK IS BENT IN THIS LOCATION. THE REAR BEDROOM HAS A ROOF CUT OUT IN THE DIMENSION OF 4 X 6 FOOT OPENING. THIS BEDROOM ALSO HAS THE T1-11 SIDING WITH DECO BEAMS IN THE CEILING. THERE ARE TWO WINDOW OPENINGS WITH BROKEN PANES THAT WERE BOARDED BY BATHCREST. A 10 FOOT SECTION OF EVE AREA WAS BURNT AND HAS ALLIGATORING OUTSIDE THE FRONT BEDROOM AREA. THERE ARE EXPOSED CONDUCTORS IN THE HALLWAY SOFFIT AREA AND THE FRONT BEDROOM WITH HEAT DAMAGED AND WALL SWITCHES THAT HAVE MELTED. THE LAUNDRY ROOM HAS A CEILING LIGHT FIXTURE WITH HEAT DAMAGE. THERE IS SEVER SMOKE DAMAGE TO THE ENTIRE HOME. TEP DID PULL THE METER, SWG PINNED THE GAS METER OFF. PERMIT ARE REQUIRED TO MAKE ALL REQUIRED REPAIRS THE DWELLING WAS CONDEMNED UNFIT TO OCCUPY. PHOTOS IN SIRE. SCHEDULE A 60 DAY FOLLOW INSPECTION
11/16/2011 INSP - FOLLOW UP CODE ENFORCE AVINDIOL Approved 11/16/11 BACK ON SITE HOME WAS COMPLETE // WORKERS ON SITE JUST DOING LANDSCAPING // CHECKED PERMITS AND WERE FINALED ON 11/10/11 // MOVE TO CLOSE //AV

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T10DV08985
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 9
Date Name
12/17/2010 CONTACTED IN PERSON
12/17/2010 CONTACTED BY MAILING
12/17/2010 NOTICE AND ORDER ISSUED
12/17/2010 NOTICE OF VIOLATION ISSUED
11/17/2011 VIOLATION CLOSED
08/26/2011 SEC LEIN PLACED ON PROPERTY IN THE AMOUNT OF ???
03/29/2011 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS
03/29/2011 STRUCTURE SECURED BY ???
12/17/2010 CALLBACK

Documents

File Name Document Type  
PC050001.JPG DOCUMENTS VIEW
PC050002.JPG DOCUMENTS VIEW
PC050003.JPG DOCUMENTS VIEW
PC050004.JPG DOCUMENTS VIEW
PC050005.JPG DOCUMENTS VIEW
PC050006.JPG DOCUMENTS VIEW
PC050007.JPG DOCUMENTS VIEW
PC050008.JPG DOCUMENTS VIEW
PC050009.JPG DOCUMENTS VIEW
PC050010.JPG DOCUMENTS VIEW
PC050011.JPG DOCUMENTS VIEW
PC050012.JPG DOCUMENTS VIEW
PC050013.JPG DOCUMENTS VIEW
PC050014.JPG DOCUMENTS VIEW
PC050015.JPG DOCUMENTS VIEW
EMER DOC 12-16-10.PDF DOCUMENTS VIEW
2902 E CALLE GLORIETTA.JPG DOCUMENTS VIEW
CONSTRUCTION ON NEW ROOF .JPG DOCUMENTS VIEW
FRONT VIEW .JPG DOCUMENTS VIEW