Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

12/03/2010

Applicant:

JOE RAMOS & MAI THI RAMOS

Description:

#107 FLOOR CRACKED BEHIND TOILET, WINDOWS DO NOT LOCK, LIGHT SOCKET HANGING.

Case Violations

Case Number: T10DV08741
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 10
Violation Date Code Statue
01/10/2011 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
01/10/2011 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
01/10/2011 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
01/10/2011 T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition.
01/10/2011 T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism.
01/10/2011 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
01/10/2011 T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced.
01/10/2011 T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition.
01/11/2011 T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition.
01/12/2011 T.C. Ch. 16, Sec. 16-12(a)(3) BOARDED WINDOW OR DOOR OPENINGS. a. No occupied structure may have boarded window or door openings, except as necessary on a temporary basis to keep the structure secure while under repair. b. While vacant structures may temporarily be secured by boarding up window and door openings in accordance with section 16-14(b), having or maintaining boarded window or door openings on a vacant structure for 180 days or more in any one-year period is prohibited.

Outstanding Inspections

Case Number: T10DV08741
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
12/03/2010 NPO(EL)-WIRING/SWITCH/OUTLT/FX JEBOT Item initialized
12/03/2010 NPO - INT. BUILDING MAINTENANC JEBOT Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T10DV08741
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/07/2011 INSP - INITIAL CODE ENFORCMENT CBIGMAN Approved FOUND THE FOLLOWING: #107 WATER HEATER LACKS TPRV, ELECTRICAL SOCKETS INOP OUTLET NEXT TO KIT & BATH SINK NO GFCI, SMOKE DETECTOR INOP, ELECTRIC SOCKET NEXT TO REFRIDGERATOR INOP. #102 HAS REFUSE, BROKEN WINDOW #103, 202, 201, 209, 108, 105 NO LIGHT GLOBE FOR EXTERIOR LIGHT #150 HAS REFUSE #108 WEATHER STRIPPING, FIRE EXTINGUISHER MISSING. #204 SMOKE DETECTOR INP, WINDOWS IN BATHROOM, KITCH, INOP, CABINET DOOR IN KITCHENS COMING OFF HINGES, STAIRS AT BUILDING 2 TOP STEP IS DILAPIDATED AND PRESENTS AN IMMENENT HAZARD TO OCCUPANTS ON SECOND FLOOR. SCUFFER MISSING AND A RUSTED EXPOSING BUILDING FOUNDATION TO WATER.
04/01/2011 INSP - FOLLOW UP CODE ENFORCE CBIGMAN Approved MET W/OWNER PERMIT FINALED OUT AND REST OF THE ITEMS ON THE LIST ABATED. CLOSE CASE OUT.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T10DV08741
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
01/10/2011 CONTACTED BY PHONE
01/13/2011 CONTACTED BY MAILING
01/13/2011 NOTICE OF VIOLATION ISSUED
04/05/2011 VIOLATION CLOSED