Case: T10DV08687
Case Details
Entered Date:
12/02/2010
Applicant:
BA TRAN & CAM-GIANG THI NGUYEN
Description:
Short circuit in living room and kitchen, power keeps going off. Circuit breakers are not tripped and nothing is wrong at the meter. Power goes off every 40 min or so.
Case Violations
Case Number: T10DV08687
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 1
| Violation Date | Code Statue |
|---|---|
| 12/10/2010 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
Outstanding Inspections
Case Number: T10DV08687
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2010 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | JHURD | Notice of violation |
Completed Inspections
Case Status: COMPLIAN
Case Number: T10DV08687
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/10/2010 | INSP - INITIAL CODE ENFORCMENT | JHURD | Approved | RECIEVED CASE PACKET. 12/09/10 UNIT B 12/10/10: VISITED SITE: MET W/ OCCUPANTS. WENT OVER ISSUES. ELECTRIC WHEN IN USE GOES OUT THROUGH OUT APT. ALL APPLIANCES, CIRCUITS. THEN WILL COME BACK ON BY ITS SELF, IF APPILANCE OR SOMETHING LEFT ON CREATES A HAZARDOUS CONDITION. WHILE INSP. ON SITE. OCCUPANTS TURNED ON LIVING ROOM LAMP, ELECTRIC WENT OUT. THEN TURNED ON STOVE ELECTRIC CAME BACK ON ? INSP. REMOVED SUBPANEL COVER. VISIBLE BUZZ BAR, BREAKER SPADES HEAVILY TARNISHED FROM OVER HEATING. PITTING. WHEN ELECTRIC GOES OUT BREAKERS DO NOT TRIP. WHEN ELECTRIC COMES BACK ON SURGES. HAZARDOUS.- N/O/V SHORT TIME FRAME. 24 HOURS. |
| 12/20/2010 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Approved | CALLED OUT TO PROPERTY BY MANAGEMENT. ELECTRICAL CONTRACTOR ON SITE. MANAGEMENT PUT OUT TO BID. J.T. ELECTRIC HIRED TO DO JOB. 12/20/10 (10 DAYS) INTERIOR BUSE BAR BEING REPLACED, ANOTHER PROBLEM LOCATED IN MAIN SERVICE. BREAKER AND BUSE BAR IN NEED OF REPLACEMENT. (PER ELECTRICAN) APPROVAL HAS TO COME FROM OWNERS IN VEGAS. TIME RUNNING OUT. RECIEVED CALL LATE AFTERNOON, ELECTRICAN CAN NOT RESTORE ELECT TO UNIT. HAS TO ORDER PART. WILL BE A COUPLE OF DAYS TO ARRIVE. IF APPROVED BY OWNERS. CITY CONDEMS UNIT DUE TO LACK OF ELECTRIC. TO INCLUDE BUT NOT LIMITED TO: LACK OF ALL COOKING APPLIANCES, LACK OF POTABLE HOT WATER, LACK OF HEAT. TALKED WITH MANAGEMENT IN REGARDS TO PLACEMENT OF OCCUPANTS. HAVE TO WAIT FOR APPROVAL. AROUND 5-6 AGEED WILL PLACE OCCUPANTS. OTHER ISSUES ON SITE TO INCLUDE: ALL EXTERIOR APT. AND HALLWAY LIGHTING NOT WORKING. COURT YARD/PARKING LIGHTS INSTALLED W/O PERMIT, LIGHTS INSTALLED ON EXTERIOR WALL NO BOXES, EXPOSED ROMEX. ON ROOF TOP AND WALLS. N/O/V TO BE ISSUED FOR LIGHTING ISSUES. UNIT POSTED. N/O/V ISSUED FOR UNIT B. NO ELECT. TALKED WITH MANAGER VICTOR AND MELISA ON SEVERAL OCCASSIONS WITH SEVERAL ISSUES. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T10DV08687
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 12/10/2010 | CONTACTED BY PHONE |
| 12/17/2010 | CONTACTED BY MAILING |
| 02/16/2011 | VIOLATION CLOSED |
| 01/10/2011 | RESEARCH |
| 12/13/2010 | NOTICE OF VIOLATION ISSUED |