Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

11/24/2010

Applicant:

DOUG FIEPKER

Description:

Hazardous electrical: Main breaker popping/outlets sparking in kitchen area and throughout unit/wires hanging out of roof in kitchen area. Reported to Owner on Monday, 11/22/10. Someone went out to look at on Monday night, but nothing has been done to correct matter. Note: Inspector please contact caller prior to going out for inspection. Best time to do inspection is after 9 am and before 2 pm.

Outstanding Inspections

Case Number: T10DV08560
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
12/03/2010 NPO(EL)-MAIN/PANEL/SUB/DISCONT CBIGMAN Notice of violation
12/03/2010 NPO(EL)-WIRING/SWITCH/OUTLT/FX CBIGMAN Notice of violation

Completed Inspections

Case Status: COMPLIAN
Case Number: T10DV08560
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
11/30/2010 INSP - INITIAL CODE ENFORCMENT CBIGMAN Approved FOUND OUTLET COVER MISSING IN BACK BEDROOM, DBL LUGGING AT DISCONNECT BOX, WEATHER STRIPPING AT FRONT DOOR MISSING LARGE GAPS IN DOOR AREA, BACK DOOR WON'T OPEN, WATER HEATER MISSING TPRV, COLD WATER SHUT OFF VALVE NOT LOCATED AT THE TOP OF THE WATER HEATER (OWNER MENTIONED HIS FRIEND REPLACED OUT THE WATER HEATER), WATER HEATER APPEARS TO HAVE BEEN REPLACED AND MODIFIED THE WATER HEATER CLOSET DOOR IS BROKEN IN HALF AND LAYING ON THE GROUND NEXT TO THE WATER HEATER.
02/11/2011 INSP - FOLLOW UP CODE ENFORCE CBIGMAN Approved ABATED CLOSE CASE

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T10DV08560
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 9
Date Name
12/01/2010 CONTACTED BY PHONE
12/03/2010 CONTACTED BY MAILING
12/03/2010 NOTICE OF VIOLATION ISSUED
02/17/2011 VIOLATION CLOSED
12/01/2010 T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools.
12/01/2010 T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced.
12/01/2010 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
01/11/2011 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (4) All plumbing fixtures shall be connected to a public sewer system or to an approved private sewage disposal system, with the connections free from leaks, blockages, or other defects. All plumbing fixtures shall be connected to an approved system of water supply and provided with hot and cold running water necessary for its normal operation.
12/01/2010 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.