Case: T10DV08124
Case Details
Entered Date:
11/09/2010
Applicant:
D & B PROPERTIES 808 LINDEN LLC ATTN: DAVID FRAIM
Description:
ROOF LEAKING - NO SMOKE DETECTORS - EXPOSED WIRING AROUND THE HOUSE
Case Violations
Case Number: T10DV08124
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 7
Violation Date | Code Statue |
---|---|
12/27/2010 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
12/27/2010 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
12/27/2010 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
12/27/2010 | T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition. |
12/27/2010 | T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced. |
12/27/2010 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
12/27/2010 | T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. |
Outstanding Inspections
Case Number: T10DV08124
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 6
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/27/2010 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | RMENDOZA | Notice of violation | |
12/27/2010 | NPO(PL)-PLUMBING SYSTEM & FX | RMENDOZA | Notice of violation | |
12/27/2010 | NPO(PL)-WATER HEATERS | RMENDOZA | Notice of violation | |
12/27/2010 | NPO - SMOKE ALARMS | RMENDOZA | Notice of violation | |
12/27/2010 | NPO - EXT. BUILDING MAINTENANC | RMENDOZA | Notice of violation | |
12/27/2010 | NPO - INT. BUILDING MAINTENANC | RMENDOZA | Notice of violation |
Completed Inspections
Case Status: COMPLIAN
Case Number: T10DV08124
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/16/2010 | INSP - INITIAL CODE ENFORCMENT | RMENDOZA | Approved | WATER LEAK AT GARBAGE DISPOSAL. KITCHEN LIGHT LACK GLOBE. IMPROPER DRAIN PIPE FOR W/H. NOT 6 INCHES FROM THE GROUND AT EXTERIOR. LACK PROPER COLD WATER SHUT OFF. APPLIANCE ROOM WALL IS OPEN. DAMAGED TILE IN THE KITCEN AT STEPS. REVERSE NUETRAL IN MASTER BEDROOM(ADDITION) WATER DAMAGE EXTERIOR CEILING NEAR REAR DOOR. ADDED WASHER/DRYER AREA, BOTH WATER LINES AND ELECTRICAL CIRCUITS. ELECTRICAL PANEL LACKS A DEAD FRONT. UNIT LACKS SMOKE DETECTORS. OPEN GROUND IN SW BEDROOM, WINDOW A/C NOT PROPERLY SEALED. MAIN BATH OUTLET IS INOP AND FAN DOES NOT WORK PROPERLY. EXCESSIVELY LARGE AMOUNT OF DIRT BUILD UP IN THE DUCT SYSTEM. FACIA ON THE EAST AND WEST SIDES IS DETERIORATED. BIRD BOARD MISSING ON THE WEST SIDE. |
02/17/2011 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | All violations abated. Close case |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T10DV08124
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date | Name |
12/27/2010 | CONTACTED BY PHONE |
01/03/2011 | CONTACTED BY MAILING |
12/27/2010 | CONTACTED BY EMAIL |
01/03/2011 | NOTICE OF VIOLATION ISSUED |
02/23/2011 | VIOLATION CLOSED |