Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES
Address:

Entered Date:

09/29/2010

Applicant:

SUNCREST APARTMENT GROUP LLC

Description:

The buildings are infested with roaches, termites and bedbugs. Plumbing acts up all the time and even the maintenance people say it's not to code. Same with the building construction too. They have fenced off pool areas where the fence is about to fall kids hop into the pool area with ease. Talk to residents of the apartments for more details. They have been told by pest control companies to tent the buildings, but instead switch companies or go without. 10-13-2010 This office recivied a number of calls from the occupants at 300 and 306 E Navajo Rd for the stairs not being secured to the wall and the hand railing that is to keep people from walking off the porch is very lose and needs to have the bolts titin or replaced. The ceiling on all floors has leaks over the porchs and needs to be repaired.

Case Violations

Case Number: T10DV06644
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 3
Violation Date Code Statue
09/30/2010 T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons.
10/13/2010 T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced.
10/13/2010 T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition.

Outstanding Inspections

Case Number: T10DV06644
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
11/10/2010 NPO(PL)-PLUMBING SYSTEM & FX ASMITH Item closed
11/10/2010 NPO - INSECTS/PESTS ASMITH Item closed
11/10/2010 NPO - EXT. HAZ/ATTRACT NUISANC ASMITH Item closed
11/10/2010 NPO - EXT. BUILDING MAINTENANC ASMITH Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T10DV06644
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
09/30/2010 INSP - INITIAL CODE ENFORCMENT ASMITH Approved Inspection found infestion of roaches in units 1109 and 1110. Talked to Chance who is here from Management group in UT. The old manager has been fired for not taking care of the place. New Manager is work all issues to get the units fixed. There was no plumbing issues at time of inspection, pool fences was with in code. Will fax NOV to Suncrest Apartment Group LLC.
11/08/2010 INSP - FOLLOW UP CODE ENFORCE ASMITH Approved All items have been fixed. Case Closed

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T10DV06644
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
10/07/2010 CONTACTED BY MAILING
10/07/2010 NOTICE OF VIOLATION ISSUED
11/08/2010 VIOLATION CLOSED