Case: T10DV05679
Case Details
Entered Date:
08/25/2010
Applicant:
BA TRAN & CAM GIANG THI NGUYEN CP/RS
Description:
Unsafe pool, and hazardous 2nd floor balcony for both buildings.
Case Violations
Case Number: T10DV05679
Case Status: COMPLIAN
Case Description: ENVIRONMENTAL
Total Violations: 5
Violation Date | Code Statue |
---|---|
09/07/2010 | T.C. Ch. 16, Sec. 16-13(g)(3) HAZARDOUS POOLS. Any swimming pool or other contained body of water that contains water 18 inches or more in depth at any point and that is wider than 4 feet at any point and is intended for swimming must be properly secured and maintained so as not to create a hazard to public safety, a health hazard or attractive nuisance, and shall be entirely enclosed by a wall, fence or other barrier that is adequate to prevent access by children. Water shall not be allowed to stagnate or to harbor insect infestation. |
09/07/2010 | T.C. Ch. 16, Sec. 16-14. Dilapidated structures; vacant and unsecured structures; buildings and structures constituting a nuisance. (a) Dilapidated structures. Buildings or structures that are so deteriorated, damaged, dilapidated, or in need of repair so as to present a threat to the health, safety and welfare of the community constitute a nuisance and shall be abated by repair, rehabilitation or demolition as provided in Article VI of this chapter. |
09/07/2010 | T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element. |
09/07/2010 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
09/07/2010 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
Outstanding Inspections
Case Number: T10DV05679
Case Status: COMPLIAN
Case Description: ENVIRONMENTAL
Total Outstanding Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/15/2010 | NPO - EXT. HAZ/ATTRACT NUISANC | JVALDEZ | Item closed | |
12/15/2010 | NPO - EXT. BUILDING MAINTENANC | JVALDEZ | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T10DV05679
Case Description: ENVIRONMENTAL
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/31/2010 | INSP - INITIAL CODE ENFORCMENT | JVALDEZ | Approved | POOL AREA DOES NOT HAVE THE RETURN SPRING ATTACHED TO THE IRON GATE. POOL WATER IS UNSANITARY. BALCONY'S BEAM SUPPORT LACKS PAINT PROTECTION BALCONY'S 2X6 DECKING LACKS PAINT PROTECTION IRON TUBING USED AS THE POOL BARRIER LACKS PAINT PROTECTION IRON TUBING USED RAILING FOR THE STAIRS AND A GUARD LACKS PAINT PROTECTION. BALCONY'S 2X6 DECKING BOARDS HAVE WOOD ROT. EXTERIOR LIGHT FIXTURES ARE MISSING AND HAVE BARE EXPOSED WIRES. PENETRATIONS FROM THE EXTERIOR TO THE INTERIOR |
12/15/2010 | INSP - FOLLOW UP CODE ENFORCE | JVALDEZ | Approved | ALL VIOLATIONS ABATED CLOSE CASE |
Completed Activity Special Conditions
Case Description - ENVIRONMENTAL
Case Number - T10DV05679
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date | Name |
09/07/2010 | CONTACTED BY PHONE |
11/16/2010 | CONTACTED IN PERSON |
09/08/2010 | CONTACTED BY MAILING |
08/25/2010 | CONTACTED BY EMAIL |
09/08/2010 | NOTICE OF VIOLATION ISSUED |
12/16/2010 | VIOLATION CLOSED |