Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE
Address:

Entered Date:

08/02/2010

Applicant:

BROWN THURMAN JR

Description:

HOUSE FIRE

Outstanding Inspections

Case Number: T10DV05056
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
10/26/2010 NPO(EL)-MAIN/PANEL/SUB/DISCONT DCOX Item closed
10/26/2010 NPO(EL)-WIRING/SWITCH/OUTLT/FX DCOX Item closed
10/26/2010 NPO(DL)-DILAPIDATED STRUCTURE DCOX Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T10DV05056
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/02/2010 INSP - INITIAL CODE ENFORCMENT JVALDEZ Approved HOUSE FIRE IN LAUNDRY / LIVING ROOM, THERE IS A 4 X 10 FOOT SECTION OF ROOF PLANKING DAMAGED. TWO RAFTERS HAVE ALLIGATORING IN THE LAUNDRY ROOM AREA TWO TO THERE FOOT SPAN. 130 SQUARE FEET DRYWALL WAS DAMAGE. CONDUCTORS INSIDE THE LAUNDRY ROOM WERE BURNT AND EXPOSED, THERE WAS ALUMINUM CONDUCTORS CONNECTED TO COPPER CONDUCTORS. THERE WAS ONE OTHER CIRCUIT DAMAGE GOING FROM LAUNDRY ROOM AREA TO A CEILING FAN IN LIVING ROOM. SMOKE DAMAGE TO THE INTERIOR OF THE DWELLING. TEP DID BOOT METER, PERMITS REQUIRED FOR ALL REPAIRS. DWELLING WAS CONDEMNED UNFIT TO OCCUPY. SCHEDULED FOLLOW INSPECTION FOR 90 DAYS OUT.
10/26/2010 INSP - FOLLOW UP CODE ENFORCE DCOX Approved Restoration permit issued and inspections being conducted. Case closed.

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T10DV05056
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
08/02/2010 CONTACTED IN PERSON
08/23/2010 NOTICE AND ORDER ISSUED
08/23/2010 NOTICE OF VIOLATION ISSUED
10/26/2010 VIOLATION CLOSED
06/28/2011 CALLBACK

Documents

File Name Document Type  
P7210012.JPG DOCUMENTS VIEW
P7210013.JPG DOCUMENTS VIEW
P7210014.JPG DOCUMENTS VIEW
P7210015.JPG DOCUMENTS VIEW
P7210016.JPG DOCUMENTS VIEW
P7210017.JPG DOCUMENTS VIEW
P7210018.JPG DOCUMENTS VIEW
P7210019.JPG DOCUMENTS VIEW
P7210020.JPG DOCUMENTS VIEW
P7210021.JPG DOCUMENTS VIEW
P7210022.JPG DOCUMENTS VIEW
DAMREPORT 2002 S OLSEN.PDF DOCUMENTS VIEW
EMERCALL 2002 S OLSEN.PDF DOCUMENTS VIEW
NOT & ORDER 2002 S OLSEN.PDF DOCUMENTS VIEW