Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

06/23/2010

Applicant:

CHENG HOLDINGS LIMITED PARTNERSHIP

Description:

Unit #1 tapping into Unit #2's elecrtical box - Unit #1 had wires melt 2 years ago, so property owner is tapping into #2 electric box.

Case Violations

Case Number: T10DV04135
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 3
Violation Date Code Statue
07/19/2010 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
07/20/2010 T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools.
07/20/2010 T.C. Ch. 16, Sec. 16-14(c) BUILDINGS AND STRUCTURES CONSTITUTING A NUISANCE. All buildings and structures are to be maintained so as not to pose a threat to the health and safety of any person or persons. The condition of a building or structure that meets any or all of the following is a public nuisance, is a violation of this chapter, and subjects the building or structure to abatement as provided in Article VI of this chapter, including demolition as provided in section 16-65: (11) The building or structure exhibits conditions that present actual or imminent hazards or dangers, or is otherwise unsafe for the purpose for which it is being used.

Outstanding Inspections

Case Number: T10DV04135
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 9
End Date Description Inspector Results Comments
09/10/2010 NPO(EL)-MAIN/PANEL/SUB/DISCONT HLOPEZ Item closed
09/10/2010 NPO(EL)-WIRING/SWITCH/OUTLT/FX HLOPEZ Item closed
09/10/2010 NPO(PL)-GAS SUPPLY/CONNECT HLOPEZ Item closed
09/10/2010 NPO(HC)-NO VENTILATION HLOPEZ Item closed
10/19/2010 NPO(PL)-PLUMBING SYSTEM & FX HLOPEZ Item closed
10/19/2010 NPO(PL)-WATER HEATERS HLOPEZ Item closed
10/19/2010 NPO - EXT. HAZ/ATTRACT NUISANC HLOPEZ Item closed
10/19/2010 NPO - EXT. BUILDING MAINTENANC HLOPEZ Item closed
10/19/2010 NPO - WORK WITHOUT PERMIT HLOPEZ Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T10DV04135
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/24/2010 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VIOLATIONS PRESENT SITE INSP. FOUND LARGE AMOUNTS OF W/O/P, ADDED ELEC. CIRCUITS, ILLEGAL GAS LINES, INSTALLATION ABS PIPING FOR VENTING & WASHING MACHINE DRAINS, USE OF UNAPPROVED ABS PIPING FOR HOT & COLD SUPPLY LINES & HOT WATER HEATERS. METAL AWNING ATTACHED TO MAIN STRUCTURE FASCIA. FIRE ESCAPE ISSUES: WROUGHT IRON ENCLOUSE LACKING QUICK RELAEASE MECHANISMS FOR BD ROOMS. HAZARDOUS STRUCTURE: RAMADA TYPE STRUCTURE, SUPPORT BEAMS SEPERATING DUE TO IMPROPER INSTALLATION & LACKING APPROVED ATTACHMENT HARDWARE. EVIDENCE OF ADVANCED WOOD WROUGHT HAS DETACHED & CAUSING STRUCTURAL HAZARD. TEMPORARY SUPPORT POST HAS BEEN INSTALLED. POSSIBLE VIOLATION OF SITE PLAN, GARAGE CONVERTED INTO HABITABLE SPACE. RESEARCH REQUIRED.
10/19/2010 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved COMPLIANCE SITE INSPECTION, REMAING VIOLATIONS ABATED, FLUE PIPING INSTALLED PER CODE REQUIREMENTS, WEATHER PROTECTION COVERS FOR EXTERIOR RECEPTACLES, EXTERIOR H & C WATER LINE INSULATED & RESECURED TO WALL AS WELL AS VENT PIPING. BLOCKED WINDOW FOR FIRE ESCAPE CLEARED. OWNER HAS COMPLIED

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T10DV04135
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
07/26/2010 CONTACTED BY MAILING
10/20/2010 VIOLATION CLOSED
07/22/2010 NOTICE OF VIOLATION ISSUED