Case: T10DV03045
Case Details
Entered Date:
05/13/2010
Applicant:
CHEN FUTAI & ZHANG GINA CP/RS
Description:
No smoke alarms, electrical outlets missing covers, roof leaks.
Case Violations
Case Number: T10DV03045
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 6
Violation Date | Code Statue |
---|---|
05/27/2010 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
05/27/2010 | T.C. Ch. 16, Sec. 16-11(b) (3) VENTILATION. b. Bathrooms, laundry rooms, water closet compartments and similar rooms shall be provided with natural ventilation by means of openable exterior openings with an area not less than 1 ½ square feet. A mechanical ventilation system connected directly to the outside may be provided in lieu of these required exterior openings for natural ventilation in bathrooms that contain a bathtub, shower or combination thereof; laundry rooms; and similar rooms. Such a system must be capable of providing 5 air changes at the rate of 50 cubic feet per minute if the system operation is intermittent; or 20 cubic feet per minute if the operation is constant. The point of discharge of exhaust air shall be at least 3 feet from any opening into the building. In bathrooms containing only a water closet, lavatory or combination thereof; or in similar rooms, ventilation may be provided with an approved mechanical recirculating fan or a similar device designed to remove odors from the room. |
05/27/2010 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
05/27/2010 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
05/27/2010 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
05/27/2010 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
Outstanding Inspections
Case Number: T10DV03045
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 4
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/22/2010 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | RMENDOZA | Item closed | |
07/22/2010 | NPO(PL)-PLUMBING SYSTEM & FX | RMENDOZA | Item closed | |
07/22/2010 | NPO(DL)-DILAPIDATED STRUCTURE | RMENDOZA | Item closed | |
07/22/2010 | NPO - SMOKE ALARMS | RMENDOZA | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T10DV03045
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/19/2010 | INSP - INITIAL CODE ENFORCMENT | RMENDOZA | Approved | INTERIOR ROOF DAMAGE AT FRONT ADDITION. NO SMOKE DETECTORS. UNSECURED OUTLET AT THE REFRIGERATOR. UNSECURED, EXPOSED AND ENERGIZED ROMEX UNDER THE KITCHEN SINK. N.W. BEDROOM FAN IS INOP. MAIN BATHROOM TOILET LEAKS. CENTER BATHROOM ELECTRICAL OUTLET COVERS DO NOT FIT PROPERLY. TOILET HANDLE STICKS. S.E. BEDROOM IS MISSING ELECTRICAL OUTLET COVER. CENTER BEDROOM SOUTH OF KITCHEN LACKS A LIGHT SWITCH. REAR BATH FAN IS TOO CLOSE TO THE SHOWER. FAN EXHAUSTS UNDER EVE AND JUST ABOVE THE WINDOW. UNSECURED PVC IS LEAKING AT THE CEILING. S.W. BEDROOM HAS AN UNSECURED OUTLET. WEST EXTERIOR WALL HAS A HOLE. WATER HEATER WATER LINE IS LEAKING. EXPOSED AND UNSECURED ROMEX AT THE EAST WALL RUNNING INTO ATTIC AREA. EXPOSED AND UNSECURED ROMEX RUNNING FROM THE BOTTOM OF THE MAIN ELECTRICAL PANEL |
07/22/2010 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | ALL VIOLATIONS ABATED. |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T10DV03045
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date | Name |
05/27/2010 | CONTACTED BY PHONE |
06/03/2010 | CONTACTED BY MAILING |
06/03/2010 | NOTICE OF VIOLATION ISSUED |
07/27/2010 | VIOLATION CLOSED |