Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

04/21/2010

Applicant:

STANFORD BIANCA L

Description:

Electrical issues occuring inside the house. Outlet crackles in the office space. Two burned outlets. Most outlets do not work. Outlets are loose.

Case Violations

Case Number: T10DV02469
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
Violation Date Code Statue
04/29/2010 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
04/29/2010 T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools.
04/29/2010 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
04/29/2010 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
04/29/2010 T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism.

Outstanding Inspections

Case Number: T10DV02469
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 6
End Date Description Inspector Results Comments
12/06/2010 NPO(EL)-WIRING/SWITCH/OUTLT/FX HLOPEZ Item closed
12/06/2010 NPO(PL)-WATER HEATERS HLOPEZ Item closed
12/06/2010 NPO(HC)-HEATING & VENTILATION HLOPEZ Item closed
12/06/2010 NPO - EGRESS HLOPEZ Item closed
12/06/2010 NPO - WORK WITHOUT PERMIT HLOPEZ Item closed
12/06/2010 NPO - INT. BUILDING MAINTENANC HLOPEZ Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T10DV02469
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/22/2010 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VIOLATIONS PRESENT. SITE INSPECTION, (1) FIRE SAFETY ISSUES, NO WORKING SMOKE DETECTORS, DOUBLE KEYED DEAD BOLT AT KITCHEN DOOR, WROUGH IRON ENCLOSURES FOR BEDROOMS LACKS QUICK RELEASE HARDWARE. (2) ELECTRICAL ISSUES, 3 PRONG RECEPTACLES INSTALLED ONTO 2 WIRE SYSTEM. 3 PRONG RECEPTACLES TESTED & SHOW OPEN GROUNDS, SOME BROKEN, OTHER NOT WORKING & OTHER SHOW ARCH MARKS. EXTERIOR ELECTRICAL VIOLATION, WHEATHER PROOF COVERS LACKING AT COOLER & EXTERIOR LAUNDRY ROOM. (3) W/O/P, NEW FURNACE & HWH INSTALLED, TRP DRAIN LINE NOT CONNECTED. (4) INTERIOR SATATION, HOUSE KEEPING ISSUES, LARGE AMOUNTS OF CLOTHES UP AGAINST RECEPTACLES IN BEDROOM POSE A FIRE SAFETY ISSUE.
11/03/2010 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved 30 DAY EXTENSION GRANTED TO OWNER FOR WORK COMPLETED TO DATE.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T10DV02469
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
07/26/2010 CONTACTED BY PHONE
05/03/2010 CONTACTED BY MAILING
04/29/2010 NOTICE OF VIOLATION ISSUED
12/07/2010 VIOLATION CLOSED
04/29/2010 RESEARCH