Case: T10DV02154
Case Details
Entered Date:
04/14/2010
Applicant:
LEON CARLOS H
Description:
MINOR HOUSEKEEPING AND MAINTENANCE ISSUES. REMOVED FROM PREVIOUS VANS CASE. SEE ATTACHED EMAIL IN CASE FILE.
Case Violations
Case Number: T10DV02154
Case Status: COMPLIAN
Case Description: VACANT AND NEGLECTED PROGRAM
Total Violations: 1
| Violation Date | Code Statue |
|---|---|
| 05/10/2010 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
Outstanding Inspections
Case Number: T10DV02154
Case Status: COMPLIAN
Case Description: VACANT AND NEGLECTED PROGRAM
Total Outstanding Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/30/2012 | NPO - EXT. BUILDING MAINTENANC | LPUMPHRE | Item closed | |
| 08/30/2012 | NPO - WORK WITHOUT PERMIT | LPUMPHRE | Item closed | |
| 08/30/2012 | NPO - INT. BUILDING MAINTENANC | LPUMPHRE | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T10DV02154
Case Description: VACANT AND NEGLECTED PROGRAM
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/04/2010 | INSP - INITIAL CODE ENFORCMENT | JHURD | Approved | VISITED SITE. MET W/OWNER CARLOS. CARLOS AGREED TO ALLOW INTERIOR INSPECTION. FRONT SECTION OF STRUCTURE HAS NO DAMAGE DUE TO FIRE. (LIVING ROOM, 2 BEDROOMS, BATHROOM.) REAR SECTION OF STRUCTURE HAS DAMAGE FROM FIRE. (KITCHEN, 2 SEPERATE ROOMS 1 WEST SIDE OF KITCHEN AND 1 EAST SIDE OF KITCHEN. WEST ROOM-JOIST DAMAGE TONGUE/GROOVE (CEILING) WOOD DAMAGED. SOUTH/WEST WALL TOP CORNER SEPERATED. STRENGHT AND STABILITY COMPERMISED. KITCHEN: OPEN, EXPOSED BURNT WIRING THROUGHOUT. WALL COVERING MISSING IN AREAS EXPOSING ALL WIRING AND STUDS. ADDITION OF SKY LIGHT THROUGH KITCHEN ROOF COMPERMISED ROOF JOIST. ADOBE WALL SEPERATING LIVING ROOM AND KITCHEN HAS LARGE CRACK. HOLES IN ROOF THROUGHOUT BACK SECTION (3-4) REAR DOORS (FRENCH) DOUBLE KEY CYLINDER LOCK EXIT COMPERMISED. ELECTRICAL SYSTEM: SERVICE PANEL BOX NO DAMAGE. ALL DAMAGE DONE WAS TO INTERIOR WIRING. 1 20 AMP BREAKER IN BOX REST OF BUSE BAR OPEN. THIS 20 AMP BREAKER WIRED TO GFCI EXTERIOR CONVENIENCE OUTLET. EXTENSION CORD PLUGED INTO CONVENIENCE OUTLET RUNS TO INTERIOR OF STRUCTURE. PLUGS INTO 2 SEPERATE POWER STRIP BARS. BOTH ARE LOADED WITH PLUGS TO SERVE AS POWER. HAZARDOUS. HIGH POTENTIAL OF FIRE. OWNER SLEEPS IN SMALL TRAILER PARKED ON WEST SIDE OF MAIN STRUCTURE. NOT SELF CONTAINED. RUNS EXTENSION CORD TO TRAILER FOR ELECTRICAL SERVICE. OWNER NOW AWARE CAN NOT SLEEP IN TRAILER. CONDEMED STRUCTURE DUE TO FIRE HAZARDS IN ELECTRICAL SYSTEM. PERMITS REQUIRED FOR REHAB OF STRUCTURE. |
| 08/28/2012 | INSP - FOLLOW UP CODE ENFORCE | LPUMPHRE | Approved | Field inspection to photograph Rehab; property no longer in VANS. Photos uploaded to Sire. |
Completed Activity Special Conditions
Case Description - VACANT AND NEGLECTED PROGRAM
Case Number - T10DV02154
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 12
| Date | Name |
| 05/10/2010 | CONTACTED BY PHONE |
| 05/10/2010 | CONTACTED IN PERSON |
| 06/14/2010 | CONTACTED BY MAILING |
| 05/10/2010 | RED CROSS / PRIMAVERA |
| 05/10/2010 | NOTICE AND ORDER ISSUED |
| 05/10/2010 | MENTOR ASSISTANCE |
| 06/15/2010 | NOTICE OF VIOLATION ISSUED |
| 08/30/2012 | VIOLATION CLOSED |
| 05/10/2010 | SEC LEIN PLACED ON PROPERTY IN THE AMOUNT OF ??? |
| 05/10/2010 | STRUCTURE SECURED BY ??? |
| 06/24/2010 | RESEARCH |
| 09/29/2010 | VANS - PENDING REHABILITATION BY CITY |