Case: T10DV01605
Case Details
Entered Date:
03/24/2010
Applicant:
PLUM TREE APARTMENTS
Description:
PLUM TREE APARTMENTS #D203 WATER LEAKING THROUGH CEILING INTO BEDROOM.
Case Violations
Case Number: T10DV01605
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
| Violation Date | Code Statue |
|---|---|
| 03/29/2010 | T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced. |
| 03/29/2010 | T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced. |
| 03/29/2010 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 03/29/2010 | T.C. Ch. 16, Sec. 16-11(f)(1) Every wall or vertical support must be sufficient to carry imposed loads safely, and must not lean, buckle, or split due to defect or lack of maintenance. |
| 03/29/2010 | T.C. Ch. 16, Sec. 16-11(g) INTERIOR SANITATION. (1) The interior of every building or structure shall be maintained free from any unsafe or unsanitary accumulation of refuse. (2) All sanitary facilities shall be installed and maintained in a safe and sanitary condition. (3) Every dwelling unit must have a kitchen, which shall include a sink. Sink drain boards and countertops adjacent to the kitchen sink shall be made of non-absorbent materials, or must be covered by a non-absorbent material. |
Outstanding Inspections
Case Number: T10DV01605
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 6
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/26/2010 | NPO(PL)-PLUMBING SYSTEM & FX | WNAVARRO | Item closed | |
| 03/29/2011 | NPO - EXT. BUILDING MAINTENANC | WNAVARRO | Item closed | |
| 03/31/2010 | NPO - INT. BUILDING MAINTENANC | WNAVARRO | Notice of violation | |
| 05/28/2010 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | WNAVARRO | Item closed | |
| 05/28/2010 | NPO(HC)-COOLING | WNAVARRO | Item closed | |
| 05/28/2010 | NPO(HC)-HEATING & VENTILATION | WNAVARRO | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T10DV01605
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/26/2010 | INSP - INITIAL CODE ENFORCMENT | WNAVARRO | Approved | VISITED SITE, INSPECTED, FOUND AS FOLLOWS, CIELING IS DILAPIDATED IN BEDROOM, WATER DAMAGED ON MID SOUTH CORNER OF BEDROOM. NO GROUND FAULT INTERRUPTER CIRCUIT IN BATHROOM NO GROUND FAULT INTERRUPTER CIRCUIT IN KITCHEN. BATHTUB TILES SHOW DAMAGE INTERNALLY, WATER DAMAGE ON TWO SIDES AND ARE BUCKLED. KITCHEN COUNTER FORMICA COUNTER TOPS ARE DAMAGED AND ARE ALLOWING WATER TO PENETRATE. HOLE IN KITCHEN CABINET(DETERIOATED. ELECTRICAL: WALL SOCKETS IN BEDROOM, LIVING ROOM, KITCHEN SHOW WEAR AND DO NOT HOLD APPLIANCE CONNECTIONS. AIR FILTER FOR AIR/HEATER IS MISSING. |
| 05/28/2010 | NPO - OTHER | WNAVARRO | Approved | |
| 03/29/2011 | INSP - FOLLOW UP CODE ENFORCE | WNAVARRO | Approved | VISITED SITE, INSPECTED, FOUND DOOR REPAIRED, CASE CLOSED, ABATED |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T10DV01605
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 03/31/2010 | CONTACTED BY PHONE |
| 03/31/2010 | CONTACTED BY MAILING |
| 03/31/2010 | NOTICE OF VIOLATION ISSUED |
| 06/04/2010 | VIOLATION CLOSED |